Omron CS1W-V680C11 User Manual page 138

V680 series, id sensor units
Table of Contents

Advertisement

SECTION 6
Controlling the ID Sensor Unit
 Copy (Two-channels ID Sensor Units Only)
This command is supported by Two-channels ID Sensor Units only. Data is read from the RF Tag for
one Antenna and written to the memory of an RF Tag in the interrogation zone for the other Antenna.
Writing to the second RF Tag is always performed with a trigger
Word address
Antenna 1 of
CS1W-V680C12
or CJ1W-V680C12
n+1
n+2
n+3
n+4
n+5
n+6
• If the Command Execution Bit is turned ON in the Unit Controls for Antenna 1, data will be read from the RF Tag for
Antenna 1 and written to the RF Tag for Antenna 2.
• If the Command Execution Bit is turned ON in the Unit Controls for Antenna 2, data will be read from the RF Tag for
Antenna 2 and written to the RF Tag for Antenna 1.
• The Communications Specification for the Antenna that writes data will always be a trigger regardless of the specified
communications method.
• The Status Flag (CIO n+8, bit 04) in the Results Information will turn ON if an error occurs in the Antenna that writes
data.
• Confirm that the Antenna that writes data is not communicating before turning ON the Command Execution Bit. If the
Antenna that writes data is communicating, the Status Flag (CIO n+8, bit 04) in the Results Information will turn ON.
• Confirm the capacity of both the RF Tag being read and the one being written before using this command. If the
Processing Address and Number of Processing Bytes for the Antenna that write data are not suitable for the RF Tag
being communicated with, the Status Flag (CIO n+8, bit 04) in the Results Information will turn ON.
RFID System
136
User's Manual
Antenna 2 of
Bit No.
CS1W-V680C12
or
CJ1W-V680C12
08 to 15
04 to 07
n+11
Command
00 to 03
n+12
00 to 15
n+13
00 to 15
n+14
00 to 15
12 to 15
storage
08 to 11
n+15
00 to 07
n+16
00 to 15
Option
Type
Bit name
Command code
09 hex
Communications
Specify the communications method for
Specification
the RF Tag to be read.
p. 85
0 Trigger
1 Single auto
Processing
0 hex
Specification
p. 70
Processing
Specify the first RF Tag address to read.
---
Address
Setting range: 0000 to FFFF hex
Number of
Specify the number of RF Tag read bytes
---
Processing Bytes
Setting range: 0001 to 0800 hex
Data Storage
0000 hex
Word Address
(rightmost 4 digits)
Data
Data Storage Area 0000 hex
Bank Specification
area
Data Storage
Word Address
(leftmost 2 digits)
Command Option
Specify the first RF Tag address to write.
Setting range: 0000 to FFFF hex
Description