Omron CS1W-V680C11 User Manual page 69

V680 series, id sensor units
Table of Contents

Advertisement

I/O Data Allocations
Special I/O Unit Area Allocations and Contents
I/O data exchange for the ID Sensor Unit is performed using the words allocated to the ID Sensor Unit
as a Special I/O Unit in the Special I/O Unit Area.
SYSMAC CS-/CJ-series PLC
Special I/O Unit Area
Allocated Words
Unit 0 CIO 2000 to CIO 2009
Unit 1 CIO 2010 to CIO 2019
Unit 2 CIO 2020 to CIO 2029
Unit 3 CIO 2030 to CIO 2039
Unit 4 CIO 2040 to CIO 2049
Unit 5 CIO 2050 to CIO 2059
Unit 6 CIO 2060 to CIO 2069
Unit 7 CIO 2070 to CIO 2079
Unit 8 CIO 2080 to CIO 2089
Unit 9 CIO 2090 to CIO 2099
Unit 10 CIO 2100 to CIO 2109
CIO 2000 + 10 × n to
Unit n
CIO 2000 + 10 × n + 9
Unit 95 CIO 2950 to CIO 2959
SYSMAC CS-/CJ-series PLC
Special I/O Unit Area
Allocated Words
CIO 2000
Unit 0
to CIO 2019 CIO 2010
to CIO 2029
CIO 2020
Unit 2
to CIO 2039 CIO 2030
to CIO 2049
CIO 2040
Unit 4
to CIO 2059 CIO 2050
to CIO 2069
CIO 2060
Unit 6
to CIO 2079 CIO 2070
to CIO 2089
CIO 2080
Unit 8
to CIO 2099 CIO 2090
to CIO 2109
CIO 2100
Unit 10
to CIO 2119
CIO 2000 + 10 × n to
Unit n
CIO 2010 + 10 × n + 9
Unit 94 CIO 2940 to CIO 2959
• The words allocated to the ID Sensor Unit in the Special I/O Unit Area are determined by the setting of the unit number
switches on the Unit's front panel. Set unit numbers so that the same words are not allocated to more than one Unit. (Refer to
p. 63 for the setting method.)
• If the same unit number is set for more than one Special I/O Unit, a fatal error (No. duplication error on CX-Programmer or Unit
Number Duplication on Programming Console), and the PLC will not operate.
I/O refresh period
Refreshed every scan
during PLC's I/O
refresh period.
Outputs (CPU to ID
Sensor Unit) are
refreshed first,
followed by inputs
(ID Sensor Unit to
CPU Unit).
I/O refresh period
Unit 1
Refreshed every scan
during PLC's I/O
Unit 3
refresh period.
Outputs (CPU to ID
Sensor Unit) are
Unit 5
refreshed first,
followed by inputs
(ID Sensor Unit to
Unit 7
CPU Unit).
Unit 9
Data Exchange with the CPU Unit
ID Sensor Unit
CS1W-V680C11/CJ1W-V680C11
I/O Data
n to
Output refresh data
n+6
n+7 to
Input refresh data
n+9
(n = CIO 2000 + 10 × unit No.)
ID Sensor Unit
CS1W-V680C12/CJ1W-V680C12
I/O Data
Antenna 1
n
Output refresh data
to n+6
Antenna 1
n+7
Input refresh data
to n+ 9
Antenna 2
n+10
Output refresh data
to n+16
Antenna 2
n+17
Input refresh data
to n+19
(n = CIO 2000 + 10 × unit No.)
SECTION 4
RFID System
67
User's Manual