Section 6.3.2.1

Configuring VLAN Tagging

On the VLAN Tagging pane, you configure the management VLAN options. The options include the VLAN
number and the 802.1p priority value. Outgoing management frames are tagged with the configured VLAN
number and priority. Incoming management frames must be tagged with the same values, or the CPE drops the
incoming frames.
Procedure: Setting the VLAN Tagging Parameters
1.
Click the Network button. The IP Settings pane appears.
2.
In the options panel, click the Ethernet Settings link. The VLAN Tagging pane appears.
Figure 66: VLAN Tagging pane
3.
View and configure the LAN and RF IP settings in the following fields:
Table: IP Settings fields
Field
VLAN ID [1-4094]
802.1p bits [0-7]
4.
Click the Apply button.
76
Description
Displays an identifier for the management VLAN.
Values: A number in the range of 1 to 4094.
Default: 0
Sets the 802.1p priority value for the management VLAN. Type a value from 0 to 7.
Values: A number in the range of 0 to 7
Default: 0