FAQ 10/2014
How to Configure the CPE
Scanner
RUGGEDCOM WIN5100, RUGGEDCOM WIN5200
http://support.automation.siemens.com/WW/view/en/103929234

Advertisement

loading

Summary of Contents for Siemens RUGGEDCOM WIN5100

  • Page 1 FAQ 10/2014 How to Configure the CPE Scanner RUGGEDCOM WIN5100, RUGGEDCOM WIN5200 http://support.automation.siemens.com/WW/view/en/103929234...
  • Page 2: Table Of Contents

    This entry is from the Siemens Industry Online Support. The general terms of use (http://www.siemens.com/terms_of_use) apply. Security Siemens provides products and solutions with industrial security functions that informa- support the secure operation of plants, solutions, machines, equipment and/or tion networks. They are important components in a holistic industrial security concept.
  • Page 3: Introduction

    1 Introduction Introduction Abbreviations & Acronyms Table 1-1 Abbreviation/Acronym Definition Base Station Customer Premises Equipment PUSC Partial Used Sub Channels Overview The CPE scanner is used for network discovery for the first-time, initial network entry or network re-entry after a link drop. The process does not apply to network entry triggered by handover.
  • Page 4: Configuration And Operation

    2 Configuration and Operation Configuration and Operation Singular Frequency and Frequency Range CPE scanner configuration includes a list of possible frequencies that can be a singular frequency or a range of frequencies. The maximum number of entries in the list is 32. Single frequency is defined by setting the Start and the End frequency to the same value and the number of steps to 0.
  • Page 5: Scan Priority And Cinr Threshold

    2 Configuration and Operation Figure 2-2: Frequency Range List Configuration Defining a start frequency as 3.473 Ghz and an end frequency of 3.583 Ghz with a step of 11 Mhz is similar to defining singular frequencies as 3.473 Ghz, 3.484 Ghz, 3.
  • Page 6 2 Configuration and Operation Figure 2-3: CINR Threshold and Priority The next figure shows a scan report at the end of a network entry. Figure 2-4: Scan Report How to Configure the CPE Scanner Entry-ID: 103929234, V 1.0, 10/2014...
  • Page 7 2 Configuration and Operation If no BS signal is received that is above the defined CINR threshold, the CPE will complete a scan of all defined frequencies in the scanner. Once the scan is complete, the CPE will try to connect to the BS with the highest CINR irrespective of the defined priorities.
  • Page 8: Pusc Mode

    2 Configuration and Operation In a case where no priorities are set for frequencies defined in the scanner, the CPE will scan all frequencies. Once the scan is complete, the CPE will try to connect to the BS with the highest CINR. Figure 2-6: No Priority PUSC MODE “PUSC mode”...