Log Management; Remote Management Parameters - Siemens RUGGEDCOM WiN5200 User Manual

Hide thumbs Also See for RUGGEDCOM WiN5200:
  • Faq (8 pages)
Table of Contents

Advertisement

RUGGEDCOM WiN5100/WiN5200
User Guide
Section 6.2.6

Log Management

On the Syslog Configuration and Log Files panes, you configure the log management options.
Procedure: Setting Syslog Configuration Options
Click the Management button. The Management options appear in the options pane.
1.
2.
In the options panel, click the Log Management link. The Syslog pane appears.
Figure 45: Syslog pane
3.
Review and set the syslog configuration parameters in the following fields:
Table: Syslog Configuration Fields
Field
Syslog Enable
Server IP
UDP Port (1-65535)
4.
Click the Apply button.
Section 6.2.7

Remote Management Parameters

On the Remote Management panes, you configure the management port, management VLAN, and DSCP
marking parameters:
Log Management
Description
Enables or disables logging.
Values: Enable | Disable
Default: Disable
Sets the IP address of the server to which log files are uploaded. Type an IPv4 address.
Values: IPv4 address
Default: 0.0.0.0
Sets the UDP port on the server to use when uploading the log files to the server. Type a value in
the range of 1 to 65535.
Values: Number in the range of 1 to 65535
Default: 514
Chapter 6
CPE Management Interface
51