Trane CVHE Installation, Operation And Maintenance Manual page 3

Water-cooled centravac chillers with tracer adaptiview control
Table of Contents

Advertisement

W W A A R R N N I I N N G G
F F o o l l l l o o w w E E H H S S P P o o l l i i c c i i e e s s ! !
F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w i i n n s s t t r r u u c c t t i i o o n n s s b b e e l l o o w w c c o o u u l l d d r r e e s s u u l l t t i i n n
d d e e a a t t h h o o r r s s e e r r i i o o u u s s i i n n j j u u r r y y . .
• •
A A l l l l I I n n g g e e r r s s o o l l l l R R a a n n d d p p e e r r s s o o n n n n e e l l m m u u s s t t f f o o l l l l o o w w
I I n n g g e e r r s s o o l l l l R R a a n n d d E E n n v v i i r r o o n n m m e e n n t t a a l l , , H H e e a a l l t t h h a a n n d d
S S a a f f e e t t y y ( ( E E H H S S ) ) p p o o l l i i c c i i e e s s w w h h e e n n p p e e r r f f o o r r m m i i n n g g w w o o r r k k
s s u u c c h h a a s s h h o o t t w w o o r r k k , , e e l l e e c c t t r r i i c c a a l l , , f f a a l l l l p p r r o o t t e e c c t t i i o o n n , ,
l l o o c c k k o o u u t t / / t t a a g g o o u u t t , , r r e e f f r r i i g g e e r r a a n n t t h h a a n n d d l l i i n n g g , , e e t t c c . . A A l l l l
p p o o l l i i c c i i e e s s c c a a n n b b e e f f o o u u n n d d o o n n t t h h e e
l l o o c c a a l l r r e e g g u u l l a a t t i i o o n n s s a a r r e e m m o o r r e e s s t t r r i i n n g g e e n n t t t t h h a a n n
t t h h e e s s e e p p o o l l i i c c i i e e s s , , t t h h o o s s e e r r e e g g u u l l a a t t i i o o n n s s s s u u p p e e r r s s e e d d e e
t t h h e e s s e e p p o o l l i i c c i i e e s s . .
• •
N N o o n n - - I I n n g g e e r r s s o o l l l l R R a a n n d d p p e e r r s s o o n n n n e e l l s s h h o o u u l l d d a a l l w w a a y y s s
f f o o l l l l o o w w l l o o c c a a l l r r e e g g u u l l a a t t i i o o n n s s . .
W W A A R R N N I I N N G G
R R e e f f r r i i g g e e r r a a n n t t M M a a y y B B e e U U n n d d e e r r P P o o s s i i t t i i v v e e
P P r r e e s s s s u u r r e e ! !
F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w i i n n s s t t r r u u c c t t i i o o n n s s b b e e l l o o w w c c o o u u l l d d r r e e s s u u l l t t i i n n
a a n n e e x x p p l l o o s s i i o o n n w w h h i i c c h h c c o o u u l l d d r r e e s s u u l l t t i i n n d d e e a a t t h h o o r r
s s e e r r i i o o u u s s i i n n j j u u r r y y o o r r e e q q u u i i p p m m e e n n t t d d a a m m a a g g e e . .
S S y y s s t t e e m m c c o o n n t t a a i i n n s s r r e e f f r r i i g g e e r r a a n n t t a a n n d d m m a a y y b b e e u u n n d d e e r r
p p o o s s i i t t i i v v e e p p r r e e s s s s u u r r e e ; ; s s y y s s t t e e m m m m a a y y a a l l s s o o c c o o n n t t a a i i n n o o i i l l . .
R R e e c c o o v v e e r r r r e e f f r r i i g g e e r r a a n n t t t t o o r r e e l l i i e e v v e e p p r r e e s s s s u u r r e e b b e e f f o o r r e e
o o p p e e n n i i n n g g t t h h e e s s y y s s t t e e m m . . S S e e e e u u n n i i t t n n a a m m e e p p l l a a t t e e f f o o r r
r r e e f f r r i i g g e e r r a a n n t t t t y y p p e e . . D D o o n n o o t t u u s s e e n n o o n n - - a a p p p p r r o o v v e e d d
r r e e f f r r i i g g e e r r a a n n t t s s , , r r e e f f r r i i g g e e r r a a n n t t s s u u b b s s t t i i t t u u t t e e s s , , o o r r n n o o n n - -
a a p p p p r r o o v v e e d d r r e e f f r r i i g g e e r r a a n n t t a a d d d d i i t t i i v v e e s s . .
N N O O T T I I C C E E
E E q q u u i i p p m m e e n n t t D D a a m m a a g g e e ! !
M M i i x x i i n n g g r r e e f f r r i i g g e e r r a a n n t t s s o o r r o o i i l l s s c c o o u u l l d d r r e e s s u u l l t t i i n n
e e q q u u i i p p m m e e n n t t d d a a m m a a g g e e i i n n c c l l u u d d i i n n g g b b e e a a r r i i n n g g d d a a m m a a g g e e , ,
i i n n t t r r o o d d u u c c t t i i o o n n o o f f a a c c i i d d s s i i n n t t o o t t h h e e c c h h i i l l l l e e r r , , o o r r c c o o n n t t i i n n u u o o u u s s
p p u u r r g g e e p p u u m m p p - - o o u u t t i i n n h h i i g g h h - - h h e e a a d d / / h h i i g g h h a a m m b b i i e e n n t t
a a p p p p l l i i c c a a t t i i o o n n s s . .
C C e e n n T T r r a a V V a a c c c c h h i i l l l l e e r r s s a a r r e e m m a a n n u u f f a a c c t t u u r r e e d d w w i i t t h h
d d i i f f f f e e r r e e n n t t r r e e f f r r i i g g e e r r a a n n t t / / o o i i l l s s y y s s t t e e m m s s : : R R - - 1 1 2 2 3 3 c c h h i i l l l l e e r r s s
u u s s i i n n g g O O I I L L 0 0 0 0 0 0 2 2 2 2 a a n n d d R R - - 5 5 1 1 4 4 A A c c h h i i l l l l e e r r s s u u s s i i n n g g
O O I I L L 0 0 0 0 3 3 3 3 4 4 / / O O I I L L 0 0 0 0 3 3 3 3 5 5 . .
V V e e r r i i f f y y p p r r o o p p e e r r r r e e f f r r i i g g e e r r a a n n t t a a n n d d o o i i l l f f o o r r y y o o u u r r c c h h i i l l l l e e r r
a a n n d d d d o o N N O O T T m m i i x x r r e e f f r r i i g g e e r r a a n n t t s s o o r r o o i i l l s s ! !
This Installation, Operation, and Maintenance manual
applies to CenTraVac™ chillers with two different
refrigerant and oil systems:
R-123 and OIL00022
R-514A and OIL00334/OIL00335
I I m m p p o o r r t t a a n n t t : : Verify proper refrigerant and oil for your
chiller before proceeding!
CVHE-SVX02M-EN
B B O O S S s s i i t t e e
. . W W h h e e r r e e
N N O O T T I I C C E E
D D o o N N o o t t U U s s e e N N o o n n - - C C o o m m p p a a t t i i b b l l e e P P a a r r t t s s o o r r
M M a a t t e e r r i i a a l l s s ! !
U U s s e e o o f f n n o o n n - - c c o o m m p p a a t t i i b b l l e e p p a a r r t t s s o o r r m m a a t t e e r r i i a a l l s s c c o o u u l l d d
r r e e s s u u l l t t i i n n e e q q u u i i p p m m e e n n t t d d a a m m a a g g e e . .
O O n n l l y y g g e e n n u u i i n n e e T T r r a a n n e e ® ® r r e e p p l l a a c c e e m m e e n n t t c c o o m m p p o o n n e e n n t t s s
w w i i t t h h i i d d e e n n t t i i c c a a l l T T r r a a n n e e p p a a r r t t n n u u m m b b e e r r s s s s h h o o u u l l d d b b e e u u s s e e d d
i i n n T T r r a a n n e e C C e e n n T T r r a a V V a a c c c c h h i i l l l l e e r r s s . . T T r r a a n n e e a a s s s s u u m m e e s s n n o o
r r e e s s p p o o n n s s i i b b i i l l i i t t y y f f o o r r d d a a m m a a g g e e s s r r e e s s u u l l t t i i n n g g f f r r o o m m t t h h e e u u s s e e
o o f f n n o o n n - - c c o o m m p p a a t t i i b b l l e e p p a a r r t t s s o o r r m m a a t t e e r r i i a a l l s s . .
Factory Warranty Information
Compliance with the following is required to preserve
the factory warranty:
A A l l l l U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n s s
Startup MUST be performed by Trane, or an authorized
agent of Trane, to VALIDATE this WARRANTY.
Contractor must provide a two-week startup
notification to Trane (or an agent of Trane specifically
authorized to perform startup).
A A d d d d i i t t i i o o n n a a l l R R e e q q u u i i r r e e m m e e n n t t s s f f o o r r U U n n i i t t s s R R e e q q u u i i r r i i n n g g
D D i i s s a a s s s s e e m m b b l l y y a a n n d d R R e e a a s s s s e e m m b b l l y y
When a new chiller is shipped and received from our
Trane manufacturing location and, for any reason, it
requires disassembly or partial disassembly, and
reassembly— which could include but is not limited to
the evaporator, condenser, control panel, compressor/
motor, economizer, purge, factory-mounted starter or
any other components originally attached to the fully
assembled unit— compliance with the following is
required to preserve the factory warranty:
Trane, or an agent of Trane specifically authorized
to perform start-up and warranty of Trane®
products, will perform or have direct on-site
technical supervision of the disassembly and
reassembly work.
The installing contractor must notify Trane—or an
agent of Trane specifically authorized to perform
startup and warranty of Trane® products—two
weeks in advance of the scheduled disassembly
work to coordinate the disassembly and
reassembly work.
Start-up must be performed by Trane or an agent of
Trane specifically authorized to perform startup and
warranty of Trane® products.
Trane, or an agent of Trane specifically authorized to
perform start-up and warranty of Trane® products, will
provide qualified personnel and standard hand tools to
perform the disassembly and reassembly work at a
location specified by the contractor. The contractor
shall provide the rigging equipment such as chain falls,
gantries, cranes, forklifts, etc. necessary for the
disassembly and reassembly work and the required
qualified personnel to operate the necessary rigging
equipment.
I I n n t t r r o o d d u u c c t t i i o o n n
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

CvhfCvhgCvhe-svx02m-en

Table of Contents