In low luminance environment, the accuracy is down of the result.
Because object color is effect to auto exposure, the accuracy is down of the result
If the object is too big, the accuracy is down of the result.
7) Cross : Cross counting mode.
 Zone : Select Cross Zone using the Left and Right buttons (Zone 1, Zone 2).
 Size : Adjust the size of the Cross zone.
 Posi : Adjust the position of the Cross zone.
 Direction : Select Cross Direction.
 Alarm Cnt : Set alarm out cross count. Alarm count number is delaying number
before output alarm.
 Reset Cnt : Cross count reset.
If object is passing so fast through the two area, counting is not operating. In this case,
adjust to expand space between two area or adjust to decrease size of
area.
If passing object is too long, counting result can be inaccuracy. In this case, adjust to
expand space between two area or adjust to decrease size of area.
If two object passing the area in the same time, the result can be inaccuracy.
8) Entrance : Entrance counting mode. The object move in through the entrance,
counting number increases.
 Size : Press Enter button adjust the size of the Entrance zone.
 Posi : Press Enter button adjust the Position of the Entrance zone.
 Alarm Cnt : Set alarm out entrance count. Alarm count number is delaying
number before output alarm.
 Reset Cnt : Entrance count reset.
Crossing object is not considered. / Several object will not be detected.
If the distance is increases between the camera and entrance, the result can be
inaccuracy.