HYDRA and REGCOM
RS-485 NETWORK DATA CABLE WIRING
(120 Ohm impedance, twisted pair)
RJ-45
Pin 4
Pin 5
Table 8: RS-485 Network Data Cable Wiring
LED STATUS INDICATION
Status light A illuminates whenever data is sent from the
Regcom to the master unit. This is the same as Network
LED on the VSI-Pro Max.
Status light B illuminates to indicate the Regcom is
correcly connectly connected via the RS-485 network to
the master unit. This is the same as the Register LED on
the VSI-Pro Max
Figure 136: VSI-Pro Max Front Panel
Dipswitch Settings
The following are the rear dipswitch settings for both the Regcom and Hydra. SW1-5 select the address for the
Regcom and the communication parameters for the Hydra. SW6 has no function. SW7 has no function for the
Hydra but selects Baud rate for the Regcom On- 57.6K, Off 9600 baud. SW8 terminates either device with 120
ohms and should be on for the Hydra and on for the last Regcom in the network.
Regcom
Addres s
SW1
SW2
---
Off
Off
1
On
Off
2
Off
On
3
On
On
4
Off
Off
5
On
Off
6
Off
On
7
On
On
8
Off
Off
9
On
Off
10
Off
On
11
On
On
12
Off
Off
13
On
Off
14
Off
On
15
On
On
16
Off
Off
VSI-Pro Max POS / Cash Register Interface
RJ-45
Pin 4
Pin 5
Figure 137: Hydra / Regcom
SW3
SW4
SW5
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
On
Off
Off
On
Off
Off
Off
On
Off
Off
On
Off
Off
On
Off
Off
On
Off
On
On
Off
On
On
Off
On
On
Off
On
On
Off
Off
Off
On
RS-232 Parameters
Baud rate
Data bits
Parity
Stop bits
Table 9: Hydra RS-232 Parameters
Network Parameters
Standard
Max line length
Cable type
Table 10: Network Parameters
Front Panel
(Note) Term
On/Off Input
SW6
SW7
SW8
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
Off
----
----
74
9600 or 57.6K
8
None
1
RS-485
4000 ft
120 Ohm twised pair
Figure 138: Hydra / Regcom
Rear Panel
Hydra Functions
Output
Regcom
VSI-ADD 9600 baud
Vnetworker
Vnetworker
Vnetworker
MVDR3000/5000
Regcom
Dallmeier Addr 1-8
Vnetworker
Dallmeier Addr 1-8
Regcom
VSI-ADD 57.6K baud
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
Table 11: Hydra / Regcom
TBD
Dipswitch Settings
TBD
TBD
APPENDIX M