Tx Baudrate; Tx Protocol; Parity; Data Bits - AVE VSI-Pro Max Operation Manual

Pos / cash register interface
Hide thumbs Also See for VSI-Pro Max:
Table of Contents

Advertisement

PROGRAMMING
TX BAUD RATE
Choices: AUTO, 1200, 2400, 4800, 9600, 14.4K, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K
This feature allows you to set the transmit baud rate to a separate device if you are looping the data back out of the
VSI-Pro.
To set the TX Baud Rate for your particular device, press the "Up" or "Down" button to move the cursor to "TX BAUD
RATE" and press "Set". The cursor will start flashing. You can now use the "Up" or "Down" buttons to make your
selection. When your selection appears, press "Set". The cursor will stop flashing and you can proceed to the next
menu item for programming.

TX PROTOCOL

This selection allows you program the protocol or format of the data that is transmitted out the TX port. This is only
available for registers that do not use the TX line of the POS/Cash Register port for emulate modes. When using the
register port for tapping then the data output in ASCII mode simulates the function of the VSI-Pro previous versions
and utilizes the same pinout connection. When using the VSI-Pro Max in the Master mode this TX line is used to
output the data in the VSI-ADD protocol to be compatible with the Hydra output to DVRs.
Choices: ASCII, VSI-ADD, VNet, Dallmeier, MVDR
NOTE: The choices in the above selection will change depending on the progreamming selections in the Network
Settings submenu. In the "Master" mode the data can be sent out the VSI-ADD format which is the standard AVE
protocol for register data which is supported by all AVE DVRs and many 3rd party DVR manufactures. The VNET
format is only support by the AVE Vnetworker PC Software. The MVDR format is a subset of the VNET format that is
supported by the AVE MVDR line of DVRs. The Dallmeier setting supports communication to the Dallmeier DVR in
Commanding mode. ASCII is not supported in the Master mode selection.

PARITY

Choices: NONE, ODD, EVEN
Press the "Up" or "Down" button to move the cursor to "PARITY" and press "Set". The cursor will start flashing. Press
the "Up" or "Down" button to cycle through the values and press "Set" when the desired value is displayed.

DATA BITS

Choices: 7 or 8
If you select 7 Data Bits, you must select "ODD" or "EVEN" Parity in the Parity menu. Press the "Up" or "Down" button
to move the cursor to "DATA BITS" and press "Set". The cursor will start flashing. Press the "Up" or "Down" button to
cycle through the values and press "Set" when the desired value is displayed.
HW HANDSHAKING
Choices: ON, OFF
Hardware handshaking is an electrical signal that tells the cash register or computer that the VSI-Pro Max is ready
to receive data. It may not be necessary and/or need not be connected to an outgoing signal from the cash register
or computer since the VSI-Pro Max does not require handshaking. The VSI-Pro Max handshaking signal is always
true signally the cash register or computer to send data.
Handshaking guarantees that the internal buffer is not over run or text is not lost. Most AVE interfaces do not
support this function. Also since the VSI-Pro has a 128K buffer this feature is generally not required.
VSI-Pro Max POS / Cash Register Interface
31