TCPIP 232 ADAPTER
TCPIP 232 ADAPTER
Interfacing the VSI-Pro Max to the cash register TCP/IP network requires the TCPIP 232 Adapter along with the VSI-
Pro Max. The IP address of the cash register is programmed into the TCPIP 232 Adapter via on-screen program-
ming. The cash register LAN cable is plugged into the adapter and the supplied additonal LAN cable is then plugged
into the cash register. Therefore this DOES NOT require an additional network port for the cash register interface or
any host programming of the router or switch. The TCPIP232 Adapter is not AutoSense so make sure the router is
set for MDI so normal straight thru cables are used.
Figure 129: Front of TCPIP 232 Adapter
CASH REGISTER
The pin-out between the TCPIP 232 Adapter and the VSI-Pro is as follows:
VSI-Pro Max POS / Cash Register Interface
WAVE TRANSFORMER
TCPIP 232
ADAPTER
Figure 131: VSI-Pro Connections with TCPIP 232 Adapter
TCPIP (DB-9M)
RXD 2
TXD 3
GND 5
Figure 132: Pin-Out for TCPIP 232 Adapter to VSI-Pro Max
Figure 130: Rear of TCPIP 232 Adapter
DC CABLE
VSI-PRO
RG-59U
VSI-Pro (DB-9M)
3 TXD
2 RXD
5 GND
70
APPENDIX K
RG-59U