Carrier Infinity 480CEN024 Installation Instruction page 28

Single-packaged gas furnance, system with 48ce/48cen series puron r-410a refr., single and tree-phase units sizes 024-060
Table of Contents

Advertisement

SYMPTOM
Compressor
and condenser
fan will not start,
Compressor
will
not start
but condenser
fan
runs
Three-phase
scroll compressor
makes excessive
noise_ and there may be a
low pressure differential,
Compressor
cycles (other than
normally
sat-
isfying UI)
Compressor
operates continuously
Excessive
head
preesure
Head
preesure
too
low
Excessive
suction
pressure
Suction
preeeure
tOO lOW
IFM does not run
IFM operation
is intermittent
Table
6--Tl'aubleshooting
Chart
CAUSE
Power failure
Fuse blown or circuit breaker tripped
REMEDY
Call power company
Replace fuse or reset circuit breaker
Defective contactor, transformer,
or high-pressure,
Replace component
loss-of-charge
or low-pressure
switch
Determine
cause and correct
Insufficient line voltage
Incorrect or faulty wiring
UI setting too high
Faulty wiring or loose connections
in compressor
cir-
cuit
Compressor
motor burned out, seized, or
internal overload open
Defective run/start capacitor, overload, start relay
One leg of 3-phase
power dead
Low input voltage (20% low)
Scroll compressor
is rotating in the wrong direction
Refrigerant
overcharge
or undercharge
Defective compressor
Insufficient line voltage
Blocked outdoor coil
Defective run/start capacitor
Faulty outdoor fan motor or capacitor
Restriction in refrigerant system
Dirty air filter
Unit undersized for load
UI temperature
set too low
Low refrigerant charge
Air in system
Outdoor coil dirty or restricted
Dirty air filter
Dirty condenser coil
Refrigerant
overcharged
Air in system
Condenser
air restricted
or air short-cycling
Low refrigerant charge
Restriction
in liquid tube
High heat load
Compressor
valves leaking
Refrigerant
overcharged
Dirty air filter
Low refrigerant charge
Metering device or low side restricted
Insufficient evaporator
airflow
Temperature
too low in conditioned
area
Outdoor ambient below 55"F
Filter drier restricted
Blower wheel not secured to shaft
Insufficient voltage at motor
Power connectors
not properly sealed
Water dripping into motor
Connectors
not firmly sealed
Check wiring diagram and rewire correctly
Lower UI temperature
setting below room tem-
perature
Check wiring and repair or replace
Determine
cause
Replace compressor
Determine
cause and replace
Replace fuse or reset circuit breaker
Determine
cause
Determine
cause and correct
Correct the direction of rotation by reversing the
3-phase
power leads to the unit. Shut down unit
to allow pressures
to equalize.
Recover refrigerant, evacuate system, and re-
charge to capacities
shown on rating plate
Replace and determine
cause
Determine
cause and correct
Determine
cause and correct
Determine
cause and replace
Replace
Locate restriction and remove
Replace filter
Decrease
load or increase unit size
Reset UI
Locate leak, repair, and recharge
Recover refrigerant, evacuate system, and re-
charge
Clean coil or remove restriction
Replace filter
Clean coil
Recover excess refrigerant
Recover refrigerant, evacuate system, and re-
charge
Determine
cause and correct
Check for leaks, repair, and recharge.
Remove restriction
Check for source and eliminate
Replace compressor
Recover excess refrigerant
Replace filter
Check for leaks, repair and recharge
Remove source of restriction
Increase air quantity
Check filtemreplace
if necessary
Reset UI
Install low-ambient
kit
Replace filter
Properly tighten blower wheel to shaft
Determine
cause and correct
Connectors
should snap easily; do not force
Verify proper drip loops in connector
wires
Gently pull wires individually to be sure they are
crimped into the housing