STATUS
(;ODE 14 - IGNITION LOCKOUT
Control willauto reset after three h ours. Refer tostatus code 3 4.
STATUS
(;ODE 15 - BLOWER MOTOR LOCKOUT
Indicates
the blower failed t oreach 250 RPM orthe blower failed
tocommunicate
within 3 0seconds
after b eing t urned ONintwo
successive
heating cycles. Control will a uto r eset after 3hours. Refer
tostatus code 4 1.
STATUS
(;ODE 21- GAS HEATING LOCKOUT
Control willNOT auto reset. Check formis-wired gas valve or
defective
control (valve relay).
STATUS C ODE 22 - ABNORMAL FLAME-PROVING
SIGNAL
Flame isproved while gas v alve i sde-energized.
Inducer willrun
until fault i scleared.
Check forleaky g as v alve o rstuck-open
gas
valve.
STATUS
(;ODE 23- PRESSURE
SWITCH DID NOT OPEN
Check forobstructed
pressure
tubing orpressure
switch stuck open.
STATUS
(;ODE 2 4- SECONDARY
VOLTAGE
FUSE I SOPEN
Check forshort circuit insecondary
voltage (24VAC) wiring.
STATUS (;ODE 25 - INVALID MODEL S ELECTION
OR
SETUP ERROR
Indicates
either the model plug ismissing orincorrect. If code
flashes 4 times onpower-up, control is defaulting tomodel
selection
stored inmemory.
Check forproper model plug number
and resistance
values per w iring diagram.
STATUS CODE 3 1- HIGH-HEAT
PRESSURE
SWITCH OR
RELAY D ID NOT CLOSE OR REOPENED
Control relay m ay bedefective.
If open l onger than f iveminutes,
inducer shuts offfor15 minutes before retry. Ifopens during blower
on-delay period, blower will come o nfortheselected
blower
off-delay. Check f orexcessive
wind, r estricted vent. d efective
inducer motor, defective
pressure
switch, lower i nducer voltage
(230VAC),
inadequate
combustion
airsupply, disconnected
or
obstructed
pressure
tubing, orlow inlet gas p ressure
(ifLGPS u sed).
STATUS
(;ODE 33-
LIMIT CIRCUIT
FAULT
Indicates
a limit or flame rollout switch is open. Blower will run for
4 minutes or until open switch remakes,
whichever
is longer. If open
longer than 3 minutes,
code changes
to lockout
13. If open less than
3 minutes
status code 33 continues
to flash until blower
shuts off.
Flame rollout switch requires
manual
reset. Check for loose blower
wheel,
restricted
vent. excessive
wind, dirty filter or restricted
duct
system, defective
switch or connections,
or inadequate
combustion
air supply (flame roll-out
switch open).
STATUS
CODE 34 - IGNITION
PROVING
FAILURE
Control
will try three more times before lockout
14 occurs.
If flame
signal lost during blower on-delay
period,
blower will come on for
the selected
blower
off-delay.
Check for
oxide buildup
on flame
sensor (clean with fine steel wool), proper
flame sense microamps
(.5 microamps
D.C. min., 4.0-6.0
nominal),
manual valve shut-off,
low
inlet
gas
pressure,
control
ground
continuity,
gas valve
defective
or turned
off,
flame
sensor
must
not be grounded,
inadequate
flame carryover
or rough ignition,
or green/yellow
wire
must be connected
to unit sheet metal.
STATUS
CODE 41 - BLOWER
MOTOR
FAULT
Indicates
the blower
failed to reach 250RPM
or the blower failed to
communicate
within the prescribed
time limits. Thirty seconds
after
being
turned ON or ten seconds
during
steady-state
operation.
STATUS
CODE
45 - CONTROL
CIRCUITRY
LOCKOUT
Auto reset after one hour lockout due to gas valve relay stuck open,
flame sense circuit failure,
or software
check error. Reset power
to
clear lockout.
Replace
control
if status code repeats.
Step 5--Indoor
Airflow
and Airflow- Adjustnmnts
UNIT
OPERATION
HAZARD
Failure to follow
this caution
may result in unit damage.
For cooling operation,
the recommended
airflow is 350 to 450
cfm for each 12,000
Btuh
of rated cooling
capacity.
For
heating
operation,
the airflow nmst produce
a temperature
rise
that falls within the range stamped
on the unit rating plate.
Table 5 shows the temperature
rise in each heating
mode. Refer to
these tables to detennine
the desired
heating
airflow for the system
being
installed.
NOTE:
Be sure that all supply-and
return-air
grilles are open, free
from obstructions,
and adjusted
properly.Airflow
can be changed
using the User Interface.
Unit
48CE(-,N)024040
48CE(-,N)030040
48CE(-,N)024060
480E(-,N)030060
480E(-,N)036060
480E(-,N)042060
480E(-,N)036090
480E(-,N)042090
480E(-,N)048090
480E(-,N)060090
480E(-,N)048115
480E(-,N)060115
480E(-,N)048130
480E(-,N)060130
_,irflow
delivery
values for external stal
Table
5--Air
Delivery.
and Temperature
Rise at Rated
Heating
Input
Heating Rise Range
(°F)
Rated Heating Input
(BTUH)
40,000
60,000
60,000
90,000
90,000
115,000
130,000
c pressure values ot up to 1" wc.
20 - 50
35 - 65
25 - 55
35 - 65
25 - 55
35 - 65
40 - 70
Motor
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
CFM
Heating Rise (°F)
Heating Mode
"Efficiency"
844
35
1093
40
1093
40
1333
50
1638
40
1917
45
1933
5O
"Comfort"
658
45
874
5O
874
5O
1213
55
1310
50
1725
50
1759
55
21