This user guide is appropriate for the following product numbers: 101010002U-SD 101020002U-SD 101030002U-SD " " USER MANUAL Release 1.0, June 2017 AMATRONIC LECTRONIC NDUSTRIES 17 Hartum St., P.O.B. 45029, Jerusalem 9777517, Israel Tel: 972-2-588-8222 Fax: 972-2-582-8875 Email: info@gamatronic.co.il Website: www.gamatronic.com...
Page 2
Gamatronic Electronic Industries Ltd. ("Gamatronic") warrants the products it manufactures to be free from defect for a period of one calendar year from the date of invoice, including the date of invoice. Gamatronic's liability is limited to repairing or replacing any defective parts in the equipment under warranty.
AMATRONIC LECTRONIC NDUSTRIES TABLE OF CONTENTS UPS ....................... 1 HEN YOU RECEIVE YOUR ........................2 YSTEM DESCRIPTION UPS ........................6 NSTALLING THE 3.1 Connecting an external battery .................... 6 3.2 Connect the G-Net to the mains ................... 7 3.3 Operating the G-Net ......................7 .....................
Page 4
AMATRONIC LECTRONIC NDUSTRIES AFETY RECAUTIONS The UPS system is designed for industrial applications and harsh environments. Nevertheless the UPS is a sophisticated power system and should be handled with appropriate care, according to the following guidelines. WARNING! HIGH TOUCH CURRENT! EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY.
Page 5
AMATRONIC LECTRONIC NDUSTRIES ’ • Do not open the cover of the UPS or the battery cabinets under any circumstances. All UPS panels and doors should be closed. • Do not insert any objects through the ventilation holes. • Do not put objects on the UPS. •...
Page 6
AMATRONIC LECTRONIC NDUSTRIES G-NET 19” UPS User Manual...
AMATRONIC LECTRONIC NDUSTRIES HEN YOU RECEIVE YOUR The G-NET UPS is delivered in a box to protect the UPS from damage. Before you open the box, inspect the box to verify it is undamaged. If you note any damage to the box, immediately notify the delivery firm. Save the UPS carton;...
AMATRONIC LECTRONIC NDUSTRIES YSTEM DESCRIPTION The G-NET series of Uninterruptible Power Supplies (UPS) is a line of advanced, true on-line UPSs which provide clean, reliable, and regulated AC power to your precision equipment. The G-NET-series UPS is suitable as a power supply for loads such as computers, telecommunication equipment, and computerized tools.
AMATRONIC LECTRONIC NDUSTRIES Figure 2: The UPS front panel Table 1: Key to Figure 3 ESCRIPTION Input voltage as measured by the UPS (Vac) Output voltage as measured by the UPS (Vac) Output frequency as measured by the UPS (Hz) Load level, as a percentage of a full load Remaining battery capacity as a percentage of a full charge.
AMATRONIC LECTRONIC NDUSTRIES Figure 3: Rear panel of 1 kVA unit Table 2: Key to Figure 3 ESCRIPTION An automatic circuit breaker protest the UPS’s input line from an over-voltage condition. Items 2 and 3 provide surge protection for a fax, modem, or telephone line. 2, 3 Item 2 is the socket for the input line, item 3 is for the output line.
AMATRONIC LECTRONIC NDUSTRIES NSTALLING THE Verify that the voltage and frequency of the ac power mains is appropriate for the UPS (115 ~300 Vac, 50 Hz). Connecting an external battery If you have received a battery box, use the supplied cable (Figure 6) to connect the battery box to the battery port on the G-Net rear panel.
AMATRONIC LECTRONIC NDUSTRIES Connect the G-Net to the mains Use the supplied cable to connect the UPS to the ac power mains. The connection on the UPS for this cable is located on the rear panel and is labeled INPUT. See Figure 3 or Figure 4. Connect the computer or other load devices to the UPS rear panel, using the sockets labeled “OUTPUT”...
AMATRONIC LECTRONIC NDUSTRIES UTOMATED COMPUTER SHUTDOWN A compact disk (CD ROM) is delivered along with the UPS. The disk contains software that can be installed on a computer. If that computer is connected to the UPS, then, the software can be used to perform an automatic, orderly shutdown of the computer in the event of an ac power outage.
Without a written agreement, Gamatronic is under no obligation to provide service after expiration of the initial warrantee period. Gamatronic will not be responsible for maintenance or changes to the UPS that are performed by an agent without written authorization from Gamatronic.
AMATRONIC LECTRONIC NDUSTRIES ECHNICAL PECIFICATIONS Table 5: Technical Specifications G-NET 19-INCH MODELS 1000 VA 2000 VA 3000 VA NPUT Voltage (Vac) 110 ~ 300, single phase, ground connection required Nominal voltage (Vac) 220/230 Maximum current (A) Rated frequency (Hz) 50 / 60 Frequency range (Hz) 45 ~ 65 UTPUT...
Page 17
Power Management Solutions Headquarters and Factory: 17 Professor Hartum Street, POB 45029, Jerusalem 9777517, Israel Gamatronic (UK) Ltd.15 Chester Road, Eaton Socon, St. Neots, Cambridgeshire PE19 8YT United Kingdom Tel: +44 (0)1480 479 889 Fax: +44 (0)1480 407 865 email: info@gamatronic.net...