Parameter Group B - Omron 3G3JX Quick Start Manual

200 v class three-phase input 0.2 to 7.5 kw; 200 v class single-phase input 0.2 to 2.2 kw; 400 v class three-phase input 0.4 to 7.5 kw
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

PARAMETER LIST
Parameter
Function name
No.
A093
Deceleration time 2
A293
2nd deceleration time 2
A094
2-step accel/decel selection
A294
2nd 2-step accel/decel selection
A095
2-step acceleration frequency
A295
2nd 2-step acceleration frequency
A096
2-step deceleration frequency
A296
2nd 2-step deceleration frequency
A097
Acceleration pattern selection
A098
Deceleration pattern setting
A101
OI start frequency
A102
OI end frequency
A103
OI start ratio
A104
OI end ratio
A105
OI start selection
A141
Operation frequency input A setting
A142
Operation frequency input B setting
A143
Operator selection
A145
Frequency addition amount
A146
Frequency addition direction
A151
VR start frequency
A152
VR end frequency
A153
VR start ratio
A154
VR end ratio
A155
VR start selection

4.3 Parameter group B

Parameter
Function name
No.
b001
Retry selection
b002
Allowable momentary power interruption time
b003
Retry wait time
b004
Momentary power interruption/undervoltage trip
during stop selection
b005
Momentary power interruption retry time
selection
b011
Starting frequency at active frequency matching
restart
b012
Electronic thermal level
b212
2nd electronic thermal level
b013
Electronic thermal characteristics selection
b213
2nd electronic thermal characteristics selection
b021
Overload limit selection
b221
2nd overload limit selection
b022
Overload limit level
b222
2nd overload limit level
b023
Overload limit parameter
b223
2nd overload limit parameter
b028
Overload limit source selection
b228
2nd overload limit source selection
b029
Deceleration rate constant at active frequency
matching restart level
b030
Active frequency matching restart level
JX Quick Start Guide
Monitoring or data range (digital operator)
0.01 to 3000.
00: Switched via multi-function input 09 (2CH)
01: Switched by setting
0.0 to 400.0
0.0 to 400.0
00: Line
01: S-shape curve
0.0 to 400.0
0. to 100.
00: Use OI start frequency [A101]
01: 0 Hz start
00: Digital operator (F001)
01: Digital operator (FREQ adjuster)
02: Input O
03: Input OI
04: RS485 communication
00: Addition (A + B)
01: Subtraction (A - B)
03: Multiplication (A x B)
0.0 to 400.0
00: Adds A145 value to output frequency
01: Subtract A145 value from output frequency
0.0 to 400.0
0. to 100.
00: Use VR start frequency [A151]
01: 0 Hz start
Monitoring or data range (digital operator)
00: Alarm
01: 0 Hz start
02: Frequency matching start
03: Trip after frequency matching deceleration stop
0.3 to 25.0
0.3 to 100.0
00: Disabled
01: Enabled
00: 16 times
01: No limit
00: Frequency at interruption
01: Max. frequency
02: Set frequency
0.2 x Rated current to 1.0 x Rated current
00: Reduced torque characteristics 1
01: Constant torque characteristics
02: Reduced torque characteristics 2
00: Disabled
01: Enabled in acceleration/constant speed operation
02: Enabled in constant speed operation
0.1 x Rated current to 1.5 x Rated current
0.1 to 3000.0
00: b022, b222 set values
01: Input terminal O
0.1 to 3000.0
0.2 x Rated current to 2.0 x Rated current
Changes
Default
during
Unit
setting
operation
15.00
Yes
s
1076 (high)
1077 (low)
151B (high)
151C (low)
00
No
0.0
No
Hz
0.0
No
Hz
00
No
0.0
No
Hz
0.
No
%
100.
01
No
01
No
-
02
00
No
0.0
Yes
Hz
00
No
0.0
No
Hz
0.
No
%
100.
01
No
Changes
Default
during
Unit
setting
operation
00
No
1.0
No
s
1.0
No
s
00
No
00
No
00
No
Rated
No
A
current
00
No
01
No
1.5 x
No
A
Rated
current
1.0
No
s
00
No
0.5
No
s
Rated
No
A
current
Modbus
address
(hex)
1078
151D
107A
151F
107C
1521
107D
107E
1080
1082
1083
1084
1085
108E
108F
1090
1091
1093
1095
1097
1098
1099
109A
Modbus
address
(hex)
10A5
10A6
10A7
10A8
10A9
1170
10AD
1527
10AE
1528
10B5
1529
10B6
152A
10B7
152B
10BB
152C
1171
1172
29