GENERAL INSTRUCTIONS

EN
BEFORE INSTALLING THIS APPLIANCE, CONTACT THE LOCAL BUILDING OR FIRE AUTHORITY AND
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. FOLLOW THE INSTALLATION
DIRECTIONS. DO NOT OPERATE WITHOUT FULLY ASSEMBLING ALL COMPONENTS.
IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
DO NOT EXPOSE THE APPLIANCE TO THE ELEMENTS (EX. RAIN, ETC.) AND KEEP THE APPLIANCE
DRY AT ALL TIMES. WET INSULATION WILL PRODUCE AN ODOUR WHEN THE APPLIANCE IS USED.
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
CHILDREN AND PETS MUST BE KEPT FROM TOUCHING THE APPLIANCE WHEN IT IS HOT. CON-
TACT YOUR LOCAL AUTHORIZED DEALER / DISTRIBUTOR FOR SAFETY SCREENS THAT MAY BE
COMBUSTIBLE MATERIAL SUCH AS FIREWOOD, WET CLOTHING, ETC. PLACED TOO CLOSE CAN
CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48"
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE NATIONAL ELECTRIC CODE ANSI/NF NO. 70-CURRENT (IN
THE UNITED STATES), OR WITH THE CURRENT CSA C22.1 CANADIAN ELECTRIC CODE (IN
NOTE: It is recommended to test the
listed components below before
installation:
Doors
Balance weights
Louvre for air intake
Flue damper
All components should be in good
operating condition before the unit is
installed.
1.
Combustion air is brought into the
appliance through the slots and
around the glass door or through
the screen.
2.
Outside air is controlled with a
damper to supplement indoor air.
The damper can only be adjusted
to be fully closed or fully open.
3.
Inside the firebox, combustion
takes place and exhausts out the
chimney.
4.
The appliance includes a flue
damper at the base of the chimney
which shall be closed when the
appliance is not in use to prevent
cold air entering the home. See
"Firebrick Installation and Damper
Operation" section.
The location of windows and doors, as well as the traffic flow in the room where the appliance is to be located
should be considered. If possible, choose a location where the chimney will pass through the house without
cutting a floor or roof joist.
W415-1676 / B / 10.26.17
FOLLOW THEIR GUIDELINES.
AVAILABLE FOR THIS PRODUCT.
(121.9CM) FROM THE FRONT OF THE APPLIANCE.
CANADA).
2
3
4
OPEN
CLOSED
OPEN
3
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz8000

Table of Contents