Saving Results With Downloaded Cable Ids (Dsp-4300) - Fluke DSP-4100 User Manual

Cableanalyzer dsp-4000 series
Hide thumbs Also See for DSP-4100:
Table of Contents

Advertisement

DSP-4000 Series
Users Manual
If you try to save an Autotest after the last ID in the range has been used, the list of
saved reports shows that no IDs are available (all are marked with a "$"). To save
additional results, set up a new range of IDs in SETUP, or use the ! Edit or
@ New softkey as described above to create a new ID for each additional
Autotest.

Saving Results with Downloaded Cable IDs (DSP-4300)

You can select a downloaded list as the source for cable IDs from the auto
increment menu in SETUP. See "Selecting a List of Downloaded IDs" in Chapter
2 for details.
Saving results with downloaded cable IDs is similar to saving with auto sequence
IDs. Follow steps 1 through 3 from the previous section "Saving Results with Auto
Sequence Enabled".
Changing the Cable ID for a Saved Autotest Report
You can change the cable identification assigned to a saved Autotest report as
follows:
1. Turn the rotary switch to SPECIAL FUNCTIONS.
2. Select View/Delete Test Reports.
3. Use D U to highlight the desired report. Press @ View Result, then
press ! View Result.
4. Press @ Rename Report. Use the editing softkeys to edit the cable
identification (refer to the softkey descriptions in Figure 3-11).
5. Press S.