Automatic Diagnostics

If an Autotest fails, you can press F to see more specific information on the
cause of the failure. Figure 3-4 shows examples of automatic diagnostics displays
for a NEXT failure and an open pin failure.
The arrow in the diagram at the top of the display shows the location of the failure.
The bottom half of the display describes the failure and suggests ways to fix the
fault. When appropriate, softkeys let you see the plot or plots relevant to the
failure. If more than one fault was found, you can use the $ Next Fault
and # Prev Fault softkeys to scroll through the diagnostics displays.
See Chapter 4 for information on the HDTDR and HDTDX plots.
Figure 3-4. Examples of Automatic Diagnostics Displays
Autotest
Automatic Diagnostics
oy09c.bmp
3
3-7