FOR YOUR SAFETY READ BEFORE LIGHTING
AWARNING
&WARNING
&CAUTION
BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
The gas valve on the G40DF(X) unit may be equipped with
either a gas control knob or gas control lever. Use only your
hand to push the lever or to tum the gas control knob. Never
use tools. If the knob will not turn or if the lever will not move
by hand, do not try to repair it. Call a qualified service tech-
nician. Force or attempted repair may result in a fire or ex-
plosion.
Placing the furnace into operation:
G40DF(X) units are equipped with an automatic hot sur-
face ignition system. Do not attempt to manually
light
burners on this furnace.
Each time the thermostat
calls
for heat, the burners will automatically
light. The igniter
does not get hot when there is no call for heat on these
units.
&WARNING
Gas Valve Operation (Figures 22, 23, and 24)
1 _ STOP! Read the safety information at the beginning of
this section.
2 - Set the thermostat to the lowest setting.
3 - Turn off all electrical power to the unit.
4 - This furnace is equipped with an ignition device which
automatically lights the burners. Do not try to light the
burners by hand.
5 - Remove the upper access panel.
6 - Honeywell
VR8205 Gas Valve with ON/OFF Switch
- Move gas valve switch to OFF. See figure 22.
Honeywell
VR8205 Gas Valve with Control Knob -
Turn knob on gas valve clockwise _
to OFF. Do not
force. See figure 23.
White Rodgers
36G Gas Valve - Move gas valve
switch to OFF. See figure 24.
7 - Wait five minutes to clear out any gas. If you then smell
gas, STOP! Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instruc-
tions. If you do not smell gas go to next step.
Honeywell VR8205 Series Gas Valve
MANIFOLD
(With On/Off Switch)
PRESSURE
MANIFOLD
SCREW
PRESSURE
(under cap)
OUTLET
DI
GAS VALVE ON/OFF SWITCH SHOWN IN OFF POSITION
FIGURE 22
Honeywell VR8205 Series Gas Valve
with Gas Control Knob
MANIFOLD
PRESSURE
. (_,_
MANIFOLD
GAS VALVE SHOWN IN OFF POSITION
FIGURE 23
White Rodgers 36G Series Gas Valve
MANIFOLD
PRESSURE
ADJUSTMENT
SCREW
(Under cover
screw)
PRESSURE
POST
GAS VALVE SHOWN IN OFF POSITION
FIGURE 24
8 - Honeywell
VR8205 Gas Valve with ON/OFF Switch
- Move gas valve switch to ON, See figure 22.
Honeywell
VR8205 Gas Valve with Control Knob -
Turn knob on gas valve counterclockwise
_
to ON,
Do not force. See figure 23.
White Rodgers
36G Gas Valve - Move gas valve
switch to ON, See figure 24.