Installation; Australian Requirements - Frymaster FilterQuick FQG30-T Installation, Operation And Maintenance Manual

Gas fryer
Table of Contents

Advertisement

1.
The appliance and its individual shutoff valve must be disconnected form the gas supply
piping system during any pressure testing of the system at test pressures in excess of ½ psi
(3.5 kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
2.1.3 Electrical Grounding Requirements
All electrically operated appliances must be grounded in accordance with all applicable national and
local codes, and, where applicable, CE codes. In the absence of local codes, the appliance must be
grounded in accordance with National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable. All units (cord connected or permanently connected) should be
connected to a grounded power supply system. A wiring diagram is located on the inside of the
fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.
This appliance is equipped with a special (grounding) plug for your protection
against electrical shock, and must be plugged directly into a properly grounded
receptacle. Do not cut, remove, or otherwise bypass the grounding prong on this
plug!
This appliance requires electrical power for operation. Place the gas control
valve in the OFF position in case of a prolonged power outage. Do not attempt to
operate this appliance during a power outage.
To ensure the safe and efficient operation of the fryer and hood, the electrical
plug for the 120-volt line, which powers the hood, must be fully engaged and
locked in its pin and sleeve socket.

2.1.4 Australian Requirements

To be installed in accordance with AS 5601, local authority, gas, electricity, and any other relevant
statutory regulations.
If casters are fitted, the installation must comply with AS5601 and AS1869 requirements.
2.2
Caster Installation
On an appliance with casters; the installation shall be made with a connector that complies with the
Standard for Moveable Gas Appliances, ANSI Z21.69 • CSA 6.16, and a quick disconnect device that
DANGER
DANGER
WARNING
2-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents