Frymaster FilterQuick FQG30-T Installation, Operation And Maintenance Manual page 16

Gas fryer
Table of Contents

Advertisement

complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 • CSA
6.9.
The front right caster may be locked with setscrews that may need to be loosened to move into
place. Once in place, the caster setscrews can be locked with the caster wheel parallel to the fryer
from front to back to ease moving the fryer in and out of the hood for cleaning and preventing the
caster from hitting the oil reservoir.
2.3
Pre-Connection Preparations
DO NOT connect this appliance to the gas supply before completing each step in
this section.
After the fryer has been positioned under the exhaust hood, ensure the following has been
accomplished:
1. Adequate means must be provided to limit the movement of fryers without depending upon
the gas line connector and the quick-disconnect device or its associated piping to limit the
appliance movement. If a flexible gas hose is used, a restraining cable must be connected at all
times when the fryer is in use. The restraining cable and installation instructions are packed
with the flexible hose in the accessories box that was shipped with your unit.
The appliance area must be kept free and clear of combustible material at all
times.
2. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the
hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour.
3. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle. NOTE: To ensure the
safe and efficient operation of the fryer and hood, the electrical plug for the 100 volt
to120-volt line, which powers the hood, must be fully engaged and locked in its pin
and sleeve socket.
b. Place the power switch in the ON position.
For fryers having controllers, verify that the display indicates the controller is on.
If the store is equipped with a hood interlock system, the hood exhaust fan should be
on. If not, the store hood interlock system is improperly wired and must be corrected.
c. Place the fryer power switch in the OFF position. Verify that the display indicates OFF. The
hood exhaust system should be off when all controllers display OFF.
4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is
configured for the proper type of gas before connecting the fryer quick-disconnect device or
piping from the gas supply line.
5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables and the data plate on the inside of the fryer door.