PROBLEM
A. Incorrect setup procedure.
Top off
B. Another function is in process.
reservoir won't
C. Dispose valve not completely
fill.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.
Top off
reservoir or vat
filling slow.
5.6
Error Log Codes
See section 1.13.2.1 in the FQ4000 Controller manual for instructions to access the
Error Log.
Code
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL
SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
PROBABLE CAUSES
closed.
Pump or line issues beyond the
scope of operator
troubleshooting.
ERROR MESSAGE
CORRECTIVE ACTION
A. Power cycle fryer by disconnecting
and reconnecting 5-pin bulk oil
control power cord on rear of fryer.
B. If a filtration or any other filter menu
function is in process or FILTER
NOW? YES/NO, CONFIRM YES/NO, or
SKIM VAT are displayed, wait until the
process is complete and try again.
C. Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E. Call you FAS for assistance.
Contact your bulk oil provider.
TEMP Probe reading out of range. Call
service.
High limit temperature is past more than
410°F (210°C), or in CE countries, 395°F
(202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and
the high limit has failed to open.
Immediately disconnect power to the fryer
and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked
out the ignition module.
ATO RTD reading out of range. Call service
Drain valve was trying to open and
confirmation is missing
Drain valve was trying to close and
confirmation is missing
Return valve was trying to open and
confirmation is missing
5-8
EXPLANATION