Frymaster FilterQuick FQG30-T Installation, Operation And Maintenance Manual page 42

Gas fryer
Table of Contents

Advertisement

REMOVE PAN
CHANGE FILTER PAD
IS VAT FULL?
SERVICE REQUIRED
ERROR PUMP NOT FILLING
SYSTEM ERROR FIXED?
ENTER CODE
FILL VAT FROM DRAIN PAN?
REMOVE PAN
IS PAN EMPTY?
5.3.2 Clogged Drain Error
The clogged drain error occurs during auto filtration when the oil level sensor detects that oil has
not completely drained from the frypot. This may be due to a clogged drain or an oil sensor failure.
Follow the instructions on the controller display to clear the error.
When this occurs the controller displays CLEAR DRAIN for 15 seconds changing to IS DRAIN
CLEAR?.
1. Clear debris from the drain using the fryer's friend and press the √ button to continue.
2. The controller displays DRAINING. Once the oil level sensor detects the oil has drained, normal
auto filtration operation resumes
7. Remove the filter pan.
8. Change the filter pad and ensure the filter pan has been
pulled forward, out of the cabinet for at least 30
seconds. Once the pan has been out for 30 seconds the
controller returns to idle cook mode. Ensure the pan is
dry and assembled correctly. Push the filter pan back
into the fryer. Ensure "P" is not displayed on the
controller.
9. Press the √ (check) button if the vat is full to continue.
The controller returns to idle cook mode. Press X if vat is
not full and the controller advances to
10. If a filtration error occurs six consecutive times, the
return valve closes. Press the √ (check) button to silence
alarm and continue.
11. The system detects oil is not returning to the vat and
service is required. Call an FAS.
12. Press the X button to continue cooking if possible. Call
your FAS to repair and reset the fryer. The error will be
re-displayed every 15 minutes until the issue is repaired.
Auto filtration and auto top off are disabled until the
fryer is reset.
13. FAS tech enters tech code to reset fryer.
14. Press the √ (check) button to fill the vat from filter pan to
continue. Follow prompts once the vat is full. Press X to
skip filling from drain pan.
15. Remove the filter pan.
16. Press the √ (check) button if the filter pan is empty and
continue to next step. Press X to continue filling the vat.
Follow the prompts once the vat is full.
17. The controller switches off.
.
5-6
.