[Trip information]
Error code
Failure code
0033
0034
0035
003A
* You can select a trip ON/OFF by parameters.
[Alarm information]
Error code
ST terminal OFF
Undervoltage in main
circuit
Retry in process
Frequency point setting
error alarm
Clear command
acceptable
Emergency stop command
acceptable
Setting error alarm /
/
An error code and data are
displayed alternately twice
each.
Display of first/last data
/
items
DC braking
Flowing out of excess
number of digits
Deceleration stop during
power failure function
activated.
Auto-stop because of
continuous operation at
the lower-limit frequency
13
Parameters in the process
of initialization
Output frequency upper
limit
Operation panel key alarm
Note 1) When the ON/OFF function is selected for DC braking (DB), using the input terminal selection parameter,
you can judge the inverter to be normal if "" disappears when opening the circuit between the terminal and CC.
Name
A communications error occurs between
CPU communications
error
Excessive torque
The automatic torque boost parameter
boosted
The motor has too small impedance.
CPU fault 2
The control CPU is defective.
CPU fault 3
The control CPU is defective.
Each message in the table is displayed to give a warning but does not cause the inverter to trip.
Name
The ST-CC circuit is opened.
The supply voltage between R, S and T is
under voltage.
In case of single phase 120V class, the
shorting-bar between P0 and PA/+ is
removed.
The inverter is in process of retry.
A momentary stop occurred.
The motor speed is being detected.
The frequency setting signals at points 1
and 2 are set too close to each other.
This message is displayed when pressing
the STOP key while an error code is
displayed.
The operation panel is used to stop the
operation in automatic control or remote
control mode.
An error is found in a setting when data is
reading or writing.
The first and last data item in the
data group is displayed.
DC braking in process
The number of digits such as frequencies
is more than 4.
(The upper digits have a priority.)
The deceleration stop during power
failure with is activated.
The automatic stop function selected with
was activated.
Parameters are being initialized to default
values.
An attempt was made to operate at a
frequency higher than 10 times the base
frequency ( or ).
The RUN or STOP key is held down for
more than 20 seconds.
The RUN or STOP key is faulty.
Description
control CPUs.
setting is too high.
Description
Close the ST-CC circuit.
Measure the main circuit supply voltage.
Connect the shorting-bar between P0 and PA/+.
The inverter restarts automatically. Be careful of the
Set the frequency setting signals at points 1 and 2
Press the STOP key again to clear the trip.
Press the STOP key for an emergency stop.
Check whether the setting is made correctly.
Press MODE key to exit the data group.
The message goes off in several tens of seconds if
Lower the frequency free unit magnification .
To restart operation, power supply reset or input an
This function is cancelled, when frequency reference
Normal if the message disappears after a while
Operate at a frequency within 10 times the base
Check the operation panel.
M-4
Remedies
Contact your Toshiba distributor.
Set a lower automatic torque boost
parameter setting.
Make an auto-tuning.
Contact your Toshiba distributor.
Contact your Toshiba distributor.
Remedies
If the voltage is at a normal level, the inverter
requires repairing.
machine because it may suddenly restart.
apart from each other.
To cancel the emergency stop, press any other key.
no problem occurs.
Note 1)
operation signal again.
reaches LL+0.2Hz or operation command is OFF.
(several seconds to several tens of seconds).
frequency.
E6581595