Counter timer block

9
Multi function
In the third section in a multi function counter block detail window, counter timer blocks are arranged by default. For a 16-bit
counter timer block, two counter timer blocks ("Counter_Timer_0"(16bit_Unsigned/Signed),
"Counter_Timer_1"(16bit_Unsigned/Signed)) are arranged. For a 32-bit counter timer block, one counter timer block
("Counter_Timer_0"(32bit_Unsigned/Signed)) is arranged.
The counter operates according to the signals of the event input terminals, the input signal event detection block, and the
latch event detection block and the count values are output.
• 16-bit multi function counter block
9 CREATING A HARDWARE LOGIC
145
9.2 Multi Function Counter Block