Fixed Cycle Output - Mitsubishi Electric MELSEC-L Series LD40PD01 User Manual

Flexible high-speed i/o control module
Table of Contents

Advertisement

10.6

Fixed Cycle Output

One pulse is output from the multi function counter block at specified cycle time.
The following describes a link and parameter example of a fixed cycle output. With the example setting, when a rise of the
input signal 0 is detected, output of the following fixed cycle pulse starts, and when a rise of the input signal 1 is detected, the
output stops. Note that this link example is for when a 32-bit unsigned multi function counter block is used.
ON
External output signal
OFF
Link and parameter
The following shows a link example of the hardware logic outline window and a link example and parameter setting example
of the multi function counter block detail window.
■Hardware logic outline window
Fixed cycle output
start signal
Fixed cycle output
stop signal
10 BLOCK LINK EXAMPLES
190
10.6 Fixed Cycle Output
Cycle time
1000ms
1000ms
Fixed cycle pulse
output