Other Programming; Pc5102 Pgm Outputs; Enable Pc5102-433 Supervision - DSC PC51O2-433NA Installation Manual

Hide thumbs Also See for PC51O2-433NA:
Table of Contents

Advertisement

S

4.1 PC5102 PGM Outputs

The PC5102-433 has two on-board Form C relay PGM outputs. Each of these can
be individually programmed to:
1. Follow main panel PGM outputs 1 to 14.
NOTE: Please refer to your System Installation Manual for available PGM outputs.
NOTE: If the PC5102-433 is connected to the PC580/PC1555/P-48/P-6B (all versions),
PC5010 v1.x, P832 v1.x or the WSS5010 1.0, 2.1, the PC5102 PGM outputs cannot
be programmed to follow main panel PGM outputs 1 or 2.
2. Activate for a programmable amount of time when a signal is received from a
wireless key programmed with output option 31 or 32 (PC5102 PGM pulse)
and the PGM output programming section [92] or [93] is programmed with
option 15 (PC5102 PGM pulse). The amount of time that the PGM outputs
can be programmed to remain on is programmed in sections [94] and/or [95].
The default activation time is 5 seconds.
3. Toggle state when a signal is received from a wireless key programmed with
option 31 or 32 and the PGM output programming section [92] or [93] is
programmed with option 16 (PC5102 PGM toggle).

4.2 Enable PC5102-433 Supervision

The control panel will supervise the PC5102-433 receiver via the Keybus after at least
one key has been enrolled on the module (see section 3.2 "Enrolling Wireless Keys").
To activate module supervision, after you enroll the first key(s):
1. Exit and then re-enter installer's programming.
2. Enter programming section [902]. Wait approximately one minute.
3. To exit press [#].
The system will generate a General System Supervisory trouble if the module is
removed from the Keybus. If you need to remove the PC5102-433 module from an
existing system, you will have to disable supervision of the PC5102-433.
NOTE
NOTE
NOTE: Deleting all wireless keys from the PC5102-433 or defaulting the PC5102-433
NOTE
NOTE
will cause a supervisory fault.
To disable PC5102-433 supervision:
1. Disconnect the PC5102-433 from the Keybus
2. Enter [✱][8][Installer 's Code].
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [✱][8][Installer's Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate
that the PC5102-433 is present on the system. On LCD keypads, scroll until
the module name PC5132 appears on the display.
3. To exit press [#].

Other Programming