• W A R N I N G •
This manual contains information on limitations regarding
product use and function and information on the limitations as to
liability of the manufacturer.
Installation
Manual
PC5132-433 NA
Version 4.2

Advertisement

Table of Contents
loading

Summary of Contents for DSC PC5132-433

  • Page 1: Installation Manual

    • W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Installation Manual PC5132-433 NA Version 4.2...
  • Page 2: Warning Please Read Carefully

    WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact Smoke detectors may not detect smoke from fires on another level with system users, it is your responsibility to bring each item in this warn- of the residence or building.
  • Page 3: Table Of Contents

    PC5132-433 Software Default ............... 9 Deleting Wireless Devices ..............9 Testing & Mounting Test the Reception of Wireless Devices ..........10 Mount the PC5132-433 and Wireless Devices ........12 Additional Notes Trouble Conditions ................13 Jamming Signal Detection ..............13 Wireless Zone Low Battery Transmission ...........
  • Page 4 • 6 digit serial numbers for all wireless devices: These new serial numbers include hexadecimal digits. Please read Section 3.1 “A note on Electronic Serial Numbers (ESN)” for more information on enrolling 6-digit devices. We are confident you will find the PC5132-433 Wireless Receiver a unique and useful control panel enhancement.
  • Page 5: Introduction

    1.1 How to Use this Manual Read this manual before you begin installing the PC5132-433. To install and set up the PC5132-433 and wireless devices, follow these steps. Refer to the sections listed below. 1. Temporarily mount and wire the PC5132-433 module (see Section 2 ).
  • Page 6: Compatible Wireless Devices

    1.3 Compatible Wireless Devices Please refer to the Instruction sheets of the following devices for more information. The PC5132-433 v4.X can receive signals from the following devices: • WLS904P-433 Motion Detector • WLS912-433 Glass Break Detector • WLS906-433 Smoke Detector •...
  • Page 7: Pc5132-433 Set Up & Wiring

    Make sure that electrical wires will not run over the antenna(s) of the module when it is mounted. When mounting the PC5132-433 in a basement, place the module as high and as close to the underside of the first floor as possible. The range of the module will be reduced if the unit is mounted below ground level.
  • Page 8: Enrolling Wireless Devices

    The WLS904P-433, WLS906-433, WLS907-433, WLS912-433, WLS914-433 and WLS925L-433 devices have both a 5-digit and a 6-digit serial number printed on them. When connecting the PC5132-433 to a PC5010 v1.x panel, enter 5-digit serial numbers only. When connecting the PC5132-433 to a PC5020 or PC5015 v2.x and higher, PC5010, PC1555, or PC580 panel enter the 6-digit serial number.
  • Page 9 Enroll Wireless Keys 1. At a system keypad, enter [✱][8][Installer’s code] to go to the Installer’s Programming section. 2. Enter programming section [804]. 3. Enter a 2-digit number [41]-[56] to assign the wireless key a slot. These numbers correspond to wireless key numbers 01-16. 4.
  • Page 10: Identified Wireless Keys

    (using [✱][5] access code programming) for this feature to work correctly. NOTE: Program these access codes on the system after you have connected the PC5132-433 to the Keybus (see section 2.4). Refer to your system Installation Manual for information on access code program- ming.
  • Page 11: Other Programming

    See your system Installation Manual, for more information on each of the above programming sections. 4.2 Enable PC5132-433 Supervision The control panel will supervise the PC5132-433 receiver via the Keybus after at least one device has been enrolled on the module (see section 3.2 “Enrolling Wireless Devices”).
  • Page 12: Enable Supervision Of Wireless Zones

    If the PC5132-433 module does not show on the keypad, one of the following conditions may be present: • the module is not connected properly to the Keybus • there is a problem with the Keybus wiring run • the module does not have enough power •...
  • Page 13: Pc5132-433 Software Default

    6. RF jamming detection is now enabled. To exit Installer programming, press [#]. 4.5 PC5132-433 Software Default Returning the PC5132-433 programming to factory default settings is a quick way to remove all the enrolled devices from the system and reset all the programming in section [804].
  • Page 14: Testing & Mounting

    5.1 Test the Reception of Wireless Devices It is very important to test the proposed placement of each wireless device before it is mounted. Following these steps will test the signal strength between the PC5132-433 and the wireless devices. You can test all of the devices together (global placement testing) or test each device individually.
  • Page 15 NOTE: Wait until the placement test of one device is shown/sounded before begin- ning to test the next device. Continue to test the devices until both the PC5132-433 and the devices are in good locations. If several wireless devices produce ‘bad’ test results, you may need to move the PC5132-433 to a better location.
  • Page 16: Mount The Pc5132-433 And Wireless Devices

    5.2 Mount the PC5132-433 and Wireless Devices When you have tested reception of the PC5132-433 with all the wireless devices (see section 5.1) and you have a good mounting location, mount the PC5132: 1. Pull the Keybus wires through the hole at the bottom of the cabinet.
  • Page 17: Additional Notes

    “Trouble” light will turn on and the keypad will beep. Press [✱][2] to display the trouble conditions. The following trouble conditions apply to the PC5132-433 and/or any enrolled devices. General System Tamper - This trouble is generated when the PC5132-433 detects an RF Jamming condition.
  • Page 18: Troubleshooting

    1. When I enter the 2-digit zone number when adding a wireless device, the keypad gives me a long beep. You cannot enter ESNs unless a PC5132-433 wireless receiver is connected to the Keybus. See section 2 for instructions on setting up and wiring the PC5132-433 module.
  • Page 19: Programming Worksheets

    Programming Worksheets [804] 5132--433 Wireless Expansion Programming • 6-digit entry is required. See Section 3.1 “A note on Electronic Serial Numbers” for details on programming 6-digit serial numbers. Zone Serial Numbers Default = 000000 [01] Zone 1 l _ ____ l _ ____ l _ ____ l _ ____ l _ ____ l _ ____ l [17] Zone 17 l _ ____ l _ ____ l _ ____ l _ ____ l _ ____ l _ ____ l [02] Zone 2...
  • Page 20 Wireless Key Serial Numbers Default = 000000 [49] Key 09 [41] Key 01 l _____ l _____ l _____ l _____ l _____ l _____ l l _____ l _____ l _____ l _____ l _____ l _____ l [50] Key 10 [42] Key 02 l _____ l _____ l _____ l _____ l _____ l _____ l l _____ l _____ l _____ l _____ l _____ l _____ l...
  • Page 21 Partition 1 Wireless Key Options Default = 00 [59] Function Key 1 Function Key 3 l _ ___ l _ ___ l l _ ___ l _ ___ l Function Key 2 Function Key 4 l _ ___ l _ ___ l l _ ___ l _ ___ l Partition 2 Wireless Key Options [60] Function Key 1...
  • Page 22 [84] Zone Device Supervision Options (17-24) Default = ON Option ON Option OFF Option 1 Zone 17 Supervision enabled Disabled l _ _______ l Option 2 Zone 18 Supervision enabled Disabled l _ _______ l Option 3 Zone 19 Supervision enabled Disabled l _ _______ l Option 4...
  • Page 23 Option 5 Wireless Key 05 on partition 2 On partition 1 l _ _______ l Option 6 Wireless Key 06 on partition 2 On partition 1 l _ _______ l Option 7 Wireless Key 07 on partition 2 On partition 1 l _ _______ l Option 8 Wireless Key 08 on partition 2...
  • Page 24: Guidelines For Locating Smoke Detectors

    Guidelines for Locating Smoke Detectors Experience has shown that all hostile fires in family living units generate smoke to a greater or lesser extent. Experiments using typical fires in family living units indicate that detectable quantities of smoke precede detectable levels of heat in most cases. In existing homes, NFPA Standard 72 requires that a smoke detector be installed outside each sleeping area and on each additional story of the family unit.
  • Page 25: Index

    Index global placement removing device 4 test 10 device 9 wireless key 5, 11 module 7 antenna 3 RF jamming 9 individual placement test 11 batteries interference 3 serial number 4 replacing 13 slot number buttons wireless key 5 programming 5 supervision jamming signal DEOL 8...
  • Page 26: Limited Warranty

    LIMITED WARRANTY Digital Security Controls Ltd. warrants the original pur- Digital Security Controls Ltd.’s liability for failure to chaser that for a period of twelve months from the date of repair the product under this warranty after a reasonable purchase, the product shall be free of defects in materials number of attempts will be limited to a replacement of and workmanship under normal use.
  • Page 27 FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.
  • Page 28 ©2001 Digital Security Controls Ltd. Toronto, Canada 1-800-387-3630 • www.dsc.com Printed in Canada 29005043 R003...