Table 6 - RTWD High Seasonal Effi ciency - R1234ze
Indicative performances
Cooling Capacity (1)
Total Power input in cooling (1)
Heating Capacity (2)
Total Power input in heating (2)
Compressor
Compressor Number per Circuit
Type
Model
Evaporator
Quantity
Type
Evaporator model
Evaporator Water Content volume
Two pass evaporator
Evap. Water Flow rate - Minimum (3)
Evap. Water Flow rate - Maximum (3)
Nominal water connection size
(Grooved coupling)
Three pass evaporator
Evap. Water Flow rate - Minimum (3)
Evap. Water Flow rate - Maximum (3)
Nominal water connection size
(Grooved coupling)
Condenser
Quantity
Type
Condenser model
Condenser Water Content volume
Two pass condenser
Cond. Water Flow rate - Minimum
Cond. Water Flow rate - Maximum
Nominal water connection size
(Grooved coupling)
Dimensions (4)
Unit Length
Unit Width
Unit Height
Weights (5)
Shipping Weight
Operating Weight
System data (6)
Nb of refrigerant circuit
Minimum cooling load %
Standard unit
R1234ze refrigerant charge Circuit1 /
Circuit 2 (6)
Oil charge Circuit1 / Circuit 2
POE Oil type
(1) Indicative performance at Evaporator water temperature: 12°C / 7°C - Condenser water temperature 30°C/35°C - for detailed performances consult
order write up.
(2) Indicative performance at Evaporator water temperature: 10°C / 7°C - Condenser water temperature 40°C/45°C - for detailed performances consult
order write up.
(3) Not applicable for Glycol application - see tables with Minimum Flow with Glycol.
(4) These dimensions are the maximum for a specifi c size, they may vary from one confi guration to another within a same size. For accurate
dimensions of a specifi c confi guration, refer to relevant submittal drawings.
(5) All weights +/-5% and are the maximum for each size and may vary from one confi guration to another for the same size (add 62kg for unit with
acoustic package) and refer to relevant drawing for a specifi c confi guration.
(6) System data are indicative and subject to change without notice. Please refer to unit nameplate data.
RLC-SVX14H-GB
RTWD
RTWD
100
110
HSE
HSE
(kW)
368
402
(kW)
75
82
(kW)
397
434
(kW)
85
93
#
1/1
1/1
M1/M1
M1/M2
#
1
1
Flooded shell and tube heat exchanger
E3AM
E3AM
(l)
91
91
(l/s)
11.8
11.8
(l/s)
43.1
43.1
(in) -
5" (139.7)
5" (139.7)
(mm)
(l/s)
7.8
7.8
(l/s)
28.7
28.7
(in) -
4"
4"
(mm)
(114.3 mm)
(114.3 mm)
#
1
1
C3AM
C3AM
(l)
99
99
(l/s)
13.0
13.0
(l/s)
47.6
47.6
(in) -
6"
6"
(mm)
(168.3 mm)
(168.3 mm)
(mm)
3395
3395
(mm)
1148
1148
(mm)
1943
1943
(kg)
3901
3902
(kg)
4092
4093
#
2
2
%
30
30
(kg)
60/60
60/60
(l)
9/9
9/9
RTWF
RTWD
120
130
HSE
HSE
438
482
90
100
473
520
101
112
1/1
1/1
Screw
M2/M2
M2/N5
1
1
E3AM
E3AM
91
91
11.8
11.8
43.1
43.1
6" (168.3
5" (139.7)
5" (139.7)
7.8
7.8
28.7
28.7
4"
4"
(114.3 mm)
(114.3 mm)
(114.3 mm)
1
1
Shell and tube heat exchanger
C3AM
C3AM
99
99
13.0
13.0
47.6
47.6
6"
6"
(168.3 mm)
(168.3 mm)
(168.3 mm)
3395
3395
1148
1148
1943
1943
3904
4060
4095
4251
2
2
30
30
60/60
60/60
9/9
11/11
OIL0066E or OIL0067E
General data
RTWD
RTWD
140
160
HSE
HSE
534
587
101
111
576
633
113
126
1/1
1/1
N5/N5
N5/N6
1
1
E4AM
E4AM
118
118
12.7
12.7
46.6
46.6
6" (168.3
mm)
mm)
8.5
8.5
31.1
31.1
4"
4"
(114.3 mm)
1
1
C4AM
C4AM
131
131
15.4
15.4
56.5
56.5
6"
6"
(168.3 mm)
3811
3811
1155
1155
1998
1998
4531
4533
4780
4782
2
2
30
30
80/80
80/80
11/11
11/11
17