Invacare TDXSP2 User Manual page 55

Base, tdx sp2 series
Hide thumbs Also See for TDXSP2:
Table of Contents

Advertisement

WARNING!
Risk of Death or Serious Injury
Failure to observe these warnings can cause an
electrical short resulting in death, serious injury,
or damage to the electrical system.
– The POSITIVE (+) RED battery cable MUST
connect to the POSITIVE (+) battery
terminal(s)/post(s).
– The NEGATIVE (-) BLACK battery cable
MUST connect to the NEGATIVE (-) battery
terminal(s)/post(s).
– NEVER allow any of your tools and/or battery
cable(s) to contact BOTH battery post(s) at the
same time. An electrical short may occur and
serious injury or damage may occur.
– Install protective caps on positive and negative
battery terminals.
– Replace cable(s) immediately if cable(s)
insulation becomes damaged.
– DO NOT remove fuse or mounting hardware
from POSITIVE (+) red battery cable mounting
screw.
1. Remove the batteries from the wheelchair. Refer to
7.2.12 Removing the Batteries from the Wheelchair,
page 51.
2. Cut the tie-wraps A that secure the battery terminal
covers B to the battery terminals.
3. Slide the RED battery terminal cover back on the red
battery cable to expose the POSITIVE battery terminal
C.
4. Slide the BLACK battery terminal cover back on the Black
battery cable to expose NEGATIVE battery terminal D.
60101831-A
5. Remove the locknut E that secures the bracket F of
the POSITIVE battery cable to the POSITIVE (+) battery
post of the battery.
6. Remove the locknut G that secures the NEGATIVE
battery cable H to the NEGATIVE (-) battery post of
the battery.
7. Discard the existing battery per local laws and
regulations. Refer to 10.2 Disposal, page 73.
8. Position battery connector bracket I or wiring harness
J onto the new 22NF battery or GP24 battery as shown.
9. Secure the NEGATIVE battery cable H to the NEGATIVE
(-) battery post with existing mounting screw K and
locknut G.
10. Secure the bracket F of the POSITIVE battery cable to
the POSITIVE (+) battery post with existing mounting
screw L and locknut E.
11. Position each battery terminal cover over top of each
battery terminal.
12. Secure battery terminal covers in place with one
tie-wrap.
13. Install batteries into wheelchair. Refer to 7.2.13
Installing Batteries into the Wheelchair, page 52.
Controls System
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tdxsp2-mcgTdxsp2-cg

Table of Contents