(2) Detaching and refitting the power cord connector cover and the interface cover

Procedure
1. Remove the power cord cover by
sliding it.
2. Release the hook of the interface cover
and then remove during twisting it.

(3) Detaching and refitting the right upper cover

Procedure
1. Remove two screws.
2. Release the hook A by twisting right
upper cover.
3. Release two hooks B by sliding the right
upper cover upward and then remove it.
Interface cover
Figure 1-5-7
Screw
Hook A
Front cover
Figure 1-5-8
1-5-5
2P7/2R0/3PN
Hook
Power cord
connector cover
Rear cover
Right upper cover
Screw
Hooks B