4. Open the front cover.
5. Grip the knob and then Pull the imaging
unit forward.
6. Release two hooks and then lift the top
cover upward.
7. Pull out FFC from the connector and
then remove the top cover assembly.
*: At the time of detaching and refitting the
top cover assembly, pull the imaging unit
out, for the container will not catch two
projection parts.
Knob
Front cover
Figure 1-5-5
Projection
parts
Container
Figure 1-5-6
1-5-4
2P7/2R0/3PN
Imaging unit
Hook
Top cover
assembly
Hook
FFC
Connector