(3) Detaching and refitting the power source PWB
Perform the following procedure when the power source PWB is to be checked or replaced.
Procedure
1. Remove the top cover (see page 1-6-2).
2. Remove the left cover (see page 1-6-3).
3. Remove the two connectors.
4. Remove the five screws and then the power
source PWB.
* Power source PWB and engine/high voltage
PWB are connected directly with the PWB
connector.
5. Check or replace the power source PWB.
6. Refit all the removed parts.
YC9
Connector
PWB
connectors
Power source PWB
Screws
Figure 1-6-37
FS-6020
Connector
Screws
1-6-29