Error Code; The Signature Verification Result Display - Kyocera ECOSYS P3060dn Service Manual

Hide thumbs Also See for ECOSYS P3060dn:
Table of Contents

Advertisement

In case of the error completion.
In case of occurring an error during the firmware
update, the process is immediately interrupted
and the error message and error code are dis-
played.
Precautions
Never turn the power switch off or disconnect the USB memory during the firmware update.

Error code

Code
0000
Others
0100
There is no master file.
0200
Master file version discrepancy
03xx
There is no download file (No.xx).
04xx
File (No.xx) check sum discrepancy
05xx
File (No.xx) preparation failure
06xx
File (No.xx) preparation failure
08xx
File (No.xx) writing failure
*1: The expiration of the FM certification is also included.
*2: Since the normal start-up is available next time, it is restarted automatically and starts up normally.
*3: As there is a possibility that normal start-up is impossible next time, without restarting automatically, and
move to USB update mode.

The signature verification result display

Official signature verification file
Both certificate and signature files exist and verification is suc-
cessful.
Both certificate and signature files exist but verification is unsuc-
cessful.
Neither certificate nor signature files exist.
Or either of them does not exist.
Error contents
F W - U p d a t e
E r r o r
[ C P K G ]
2 T 6 . S 0 0 0 . 0 0 1 . 0 0 5
[ E N G N ]
E r r o r
Code
S000
Other signature verification error *1
S001
Official signature verification file is short.
N001
Unable to connect the network *2
(There is no target to update.)
N002
Can not connect to the network *3
(There is the target to update.)
Indicate the result
1-6-4
2T6/2T7/2T8/2T9
1 / 2 4
-
-
2 / 2 4
-
-
2 4 / 2 4
0 8 0 1
Error contents
Version number
S000
S001