1-5-9 ejection section

(1) Detaching and refitting the ejection unit

Procedure
1. Remove the top cover assembly.
(See page 1-5-3)
2. Remove the right upper cover and the
right lower cover. (See page 1-5-4)
3. Remove the left upper cover.
(See page 1-5-5)
4. Remove the controller box cover.
(See page 1-5-25)
5. Pull the connector out and then release
the wires from Hooks.
6. Remove three screws and then remove
the ejection unit.
7. Check or replace the ejection unit and
refit all the removed parts.
*1: 60/55/50 ppm model only
*2: 45 ppm model only
Screw
*2
Screw
Hooks
Wires
Connector
1-5-21
2T6/2T7/2T8/2T9
Ejection unit
Figure 1-5-32