Service Errors; Main Motor Error (E1 Error) - Kyocera Ecosys FS-600 Service Manual

Hide thumbs Also See for Ecosys FS-600:
Table of Contents

Advertisement

Service errors

Service errors are represented by the alternating flashing of the LEDs. Kyocera has been
using the notation of "E" and "F" codes for those information: e.g. E1 for the main motor
error, F1 for the controller checksum error, etc.
The first time flashing of the top three LEDs indicates either the letter E or F; the second
time flashing indicates the number that should follow the code, counting 1 for the
(4th)
, 2 for
CASSETTE
LED
these four LEDs enable to obtain the number for the E and F errors.
For example, the E or F number for the following error is 1+2=3.
"E"
ONLINE/A4
DATA/LETTER
MANUAL/LEGA
or
L
CASSETTE/OT
HER

Main motor error (E1 error)

Indication
Indication
Indication
Indication
(3rd), 4 for
MANUAL
DATA
"F"
"8"
"4"
"2"
"1"
Suggested causes
Suggested causes
Suggested causes
Suggested causes
Overcurrent in the main motor
circuitry due to an excessive torque.
Loose connector.
Defective CPU on the engine board.
No response from the main motor
due to the defective motor driver
(transistor).
Loose CN1 connector on main motor
board.
6-12
Troubleshooting
Service errors
(2nd), and 8 for
ONLINE
Corrective action
Corrective action
Corrective action
Corrective action
Follow the flowchart on below.
(top). Adding up
FS-600/FS-680

Advertisement

Table of Contents