(3) Detaching and refitting the right upper cover

Procedure
1. Open the front cover.
2. Remove the top cover assembly.
(See page 1-5-3)
3. Remove the slot cover.
(See page 1-5-3)
4. Remove two screws.
5. Release hook A.
6. Release two hooks B by sliding the right
upper cover upward and then remove
the right upper cover.

(4) Detaching and refitting the right lower cover

Procedure
1. Remove the right upper cover.
(See page 1-5-4)
2. Remove the inlet cover.
(See page 1-5-4)
3. Pull out the cassette.
4. Remove three screws.
5. Release two hooks by sliding the right
lower cover upward and then remove
the right lower cover.
Screw
Hook A
Front cover
Screw
1-5-4
2T6/2T7/2T8/2T9
Right upper
cover
Hooks B
Figure 1-5-5
Hooks
Screw
Right lower cover
Figure 1-5-6
Screw
Screw