(6) Detaching and refitting the operation PWB

Procedure
1. Open the top cover.
2. Remove the JAM processing procedure
sheet.
3. Remove three screws.
4. Rotate the operation PWB cover.
5. Remove the screw and then remove the
operation PWB.
6. Check or replace the operation PWB
and refit all the removed parts.
Operation panel PWB
1-5-28
2T6/2T7/2T8/2T9
Screws
Screw
JAM processing
procedure sheet
Top cover
Figure 1-5-45
Screw
Operation panel
PWB cover
Figure 1-5-46