③ LED Behavior
Set the behavior of the mute/active LED for each transmitter type. Standby mode is always represented with a pulsing red LED.
*Not available for MX400R series gooseneck microphones
④ Mute Preference
Local Mute - Individual (default): Each transmitter is muted individually.
Local Mute - All: All transmitters mute when any transmitter is muted.
External Mute: Transmitter audio is on, and muted from a 3rd-party controller.
⑤ RF Power
Determines the RF coverage of an access point.
Low: 25 ft (1mW)
Medium: 50 ft (3 mW)
Medium High: 100 ft (16 mW)
Max: 150 ft (80 mW)
⑥ Out of Range Alarm
When enabled, a transmitter will audibly beep when it is taken out of the RF coverage area. (Disabled by default.)
⑦ Back in Range Action
Transmitters can be set to automatically activate (default) or mute when they re-enter the RF coverage area.
⑧ Standby Mode
Local (default): Transmitter can individually be activated.
Global: All transmitters are activated at the same time from Standby mode.
⑨ Linking Preference
The Link procedure can be restricted to the control software by disabling the hardware Link button on the Networked Charging Station. By default, the Link
button is enabled.
⑩ Identity Preference
Determines the way the transmitter responds when it is identified from the control software:
Enabled: Beeps with flashing LEDs
Disabled: Flashing LEDs only (no sound)
⑪ Language
Determines the language of the control software.
⑫ Password Setup
The default password for the device is 'admin'. The following describes access rights for each logon:
Admin (default): Full monitoring and editing access. The Admin can enable or disable the Tech- and Guest-level logon.
Tech: Monitoring with limited editing access.
Guest: Monitoring only.
⑬ Save/Load Preferences
Saves the preferences of the Configuration as a file to the computer. The file can be loaded and will overwrite the settings for all devices in the Configuration.
⑭ Register the Product Link
Links to Shure website for product registration.

Control Software for the MXW Audio Network Interface

The MXW Audio Network Interface features a control software to mange the analog inputs and outputs of the MXW system, in addition to the 4-port gigabit
switch on the back panel of the network interface.
By default, all MXW devices have the password 'admin' applied to the control software. When logging in for the first time, enter 'admin' into the field to log on as
the administrator. The password can be changed from the Preferences tab.
Note: For optimal system performance, the control software should not be open to more than seven tabs or windows.
54/72
Active
Solid Green*
Solid Red
Solid Red
External LED Control
Shure Incorporated
Mute
Solid Red
Flashing Red
Off
2017/05/17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microflex

Table of Contents