HP XP7 User Manual page 278

Provisioning for mainf rame systems
Hide thumbs Also See for XP7:
Table of Contents

Advertisement

Item
Total Selected Capacity
Resource Group
Performance
Total Capacity
Change Pool Configuration
Total Pool Volumes
Total Capacity
*Pool Name
Initial Pool ID
Subscription Limit
Warning Threshold
Depletion Threshold
Protect V-VOLs when I/O fails to
Blocked Pool VOL
Protect V-VOLs when I/O fails to Full
Pool
278 Thin Provisioning Z and Smart Tiers Z GUI reference
Description
Displays the total capacity of the selected pool-VOLs. This item is displayed when
you select Manual as your Pool Volume Selection.
This item is displayed when you select Auto as your Pool Volume Selection.
Select the resource group name of the pool.
This item is displayed when you select Auto as your Pool Volume Selection.
Select the performance of the pool.
This item is displayed when you select Auto as your Pool Volume Selection.
Specify the total capacity of the pool.
This item is displayed when you select Auto as your Pool Volume Selection.
Opens the Change Pool Configuration Pattern window. You can change the
pool configuration that is automatically selected. For details, see
Configuration Pattern Window" (page
This item is displayed when you select Auto as your Pool Volume Selection.
Displays the total number of pool-VOLs.
This item is displayed when you select Auto as your Pool Volume Selection.
Displays the capacity of the pool created by the selected pool configuration.
Set the pool name. You can enter up to 32 case-sensitive and alphanumeric
characters.
The smallest available number is entered in the text box as a default. No number
appears in the text box if no available pool ID exists.
If you specify the pool ID which is used already, the minimum pool ID after that
the specified pool ID is automatically set.
Set the subscription limit of the pool from 0 to 65534 (%).
If this is blank, the subscription is set to unlimited.
When creating a Fast Snap pool, this setting is not necessary.
Set the threshold between 1 and 100%. The default value is 70%.
For Fast Snap: Set the threshold between 20% and 95%. The default value is
80%.
Set the threshold between 1% and 100%. The default value is 80%.
When creating a Fast Snap pool, this setting is not necessary.
This item can be set if following are satisfied:
Thin Provisioning is selected in Pool Type.
Open is selected in System Type.
Data Retention must be installed.
Select Yes or No in the protect function for THP V-VOL. If this function is enabled,
when the pool-VOL is blocked, THP V-VOL is protected from reading and writing
requests. And at the same instant, the access attribute of the THP V-VOL is
changed to the Protect attribute.
This item can be set if following are satisfied:
Thin Provisioning is selected in Pool Type.
Open is selected in System Type.
Data Retention must be installed.
Select Yes or No in the protect function for THP V-VOL. If this function is enabled,
when the pool usage reaches the full size, THP V-VOL is protected from reading
"Change Pool
324).

Advertisement

Table of Contents
loading

Table of Contents