RUGGEDCOM RX1400
Installation Guide
Technical Specifications
The following sections provide important technical specifications related to the device:
•
Section 4.1, "Power Supply Specifications"
•
Section 4.2, "Failsafe Alarm Relay Specifications"
•
Section 4.3, "Fast Ethernet Port Specifications"
•
Section 4.4, "Serial Port Specifications"
•
Section 4.5, "SFP Optic Ethernet Port Specifications"
•
Section 4.6, "Cellular Modem Specifications"
•
Section 4.7, "Operating Environment"
•
Section 4.8, "Mechanical Specifications"
Section 4.1
Power Supply Specifications
The RX1400 includes one of the following internal power supplies:
Power Supply Type
12
24
a
(T) denotes time-delay fuse.
b
Power consumption varies based on the device configuration.
Section 4.2
Failsafe Alarm Relay Specifications
Rated Switching Current
Maximum Switching Capacity
Power Supply Specifications
Input Range (V)
Minimum
9
Parameter
Max Switching Voltage
Internal Fuse Rating
Maximum
36
Value (Resistive Load)
Technical Specifications
Max. Power
a
Consumption
6.3 A(T)
< 25 W
240 VAC
125 VDC
2 A @ 240 VAC
0.15 A @ 125 VDC
2 A @ 30 VDC
150 W
500 VA
Chapter 4
b
21