The RX1400 has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
IEC 61850-3 EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-18
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
32
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Damped Oscillatory Wave
Mains Frequency Voltage
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal ports
DC Power Ports
Earth Ground Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Earth Ground Ports
Enclosure Ports
DC Power Ports
Slow Damped
2.5 kV common, 100 kHz or 1 MHz
Signal ports
DC Power Ports
DC Power Ports
Signal ports
2 kVAC (Fail-Safe Relay output)
DC Power Ports
Signal ports
Test Levels
+/- 8 kV
+/- 15 kV
20 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
10 V
40 A/m, continuous,
1000 A/m for 1 s
1000 A/m for 1 s
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
30 V Continuous, 300 V for 1s
30 V Continuous, 300 V for 1s
10%
1.5 kVDC
5 kV (Fail-Safe Relay output)
Industry Canada Compliance
RUGGEDCOM RX1400
Installation Guide
Severity
Levels
4
a
Note
4
3
3
a
Note
5
3
4
3

Advertisement