Technical Specifications

This section provides important technical specifications related to the device.
5.1

Power Supply Specifications

Note
When determining cable lengths, make sure the minimum input voltage for the
power supply is provided at the power source.
a
Power consumption varies based on the device configuration.
5.2

Failsafe Relay Specifications

Maximum Switching Voltage
5.3

Operating Environment

The RUGGEDCOM RX1512 is rated to operate under the following environmental
conditions.
Note
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1512. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the RUGGEDCOM RX1512 Series Modules Catalog.
Ambient Operating
Temperature
Ambient Storage Temperature
RUGGEDCOM RX1512
Installation Manual, 04/2021, C79000-G8976-1057-20
Power
Supply Type
Min
Internal
11 VDC
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
ab
Input Range
Max
72 VDC
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
Internal
Maximum Power
Fuse Rating
Consumption
6.3 A
26.4 W
Isolation
1500 V
for 1 minute
rms
between coil and contacts