Omron FH Series Operation Manual page 26

Vision sensor fh-1 series fh-3 series
Hide thumbs Also See for FH Series:
Table of Contents

Advertisement

1 Overview
Downloading the
settings data for
the FH sensor
controller
Uploading the
settings data for
the FH sensor
controller
1 - 6
(1) Connection through an NJ/NX-series Con-
troller (when executing an NJ/NX project)
The settings data for the FH sensor controller
is not downloaded.
Performing the data downloading from
Sysmac Studio will not download the data
that the FH sensor controller manages within
the project data that Sysmac Studio
manages. Therefore, the settings for the FH
sensor controller will not be overwritten.
There are following two methods to download
the FH settings data to the FH sensor
controller.
• Directly connecting to the FH sensor con-
troller and downloading the data
• Extracting the data from Sysmac Studio
and loading it to the FH sensor controller
via the external memory.
The settings data for the FH sensor controller
is not uploaded.
After performing the data uploading to
Sysmac Studio, all the FH settings data
values (i.e., the scene group data, the
system data, the communications command
macros, and the security settings data) that
the FH sensor controller manages within the
project data that Sysmac Studio manages will
be reset to the factory defaults.
The device variables related to the FH
sensor controller in the I/O Map are
uploaded.
There are following two methods to transfer
the settings data for the FH sensor controller
to Sysmac Studio.
• Directly connecting to the FH sensor con-
troller and uploading the data
• Save the settings data in the FH sensor
controller in the external memory and load
it to Sysmac Studio via the external mem-
ory.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
(2) Ethernet direct connection (when exe-
cuting an FH project)
Downloading the FH settings data from
Sysmac Studio is possible.
If the FH sensor controller is connected to
the computer that runs Sysmac Studio via
Ethernet, downloading the FH settings data
from Sysmac Studio to the FH sensor
controller is possible by transferring the
project data that the Sysmac Studio
manages to the FH sensor controller via the
Ethernet.
If not connected, right-click the FH sensor
controller in the Multiview Explorer and
select [Save file] from the menu to save the
data in the external memory.
Then, load the data in the external memory
to the FH sensor controller.
Uploading the settings data for the FH
sensor controller to Sysmac Studio is
possible.
If the FH sensor controller is connected to
the computer that runs Sysmac Studio via
Ethernet, loading the data in the FH sensor
controller to Sysmac Studio project is
possible by transferring the FH settings data
to the project via Ethernet.
If not connected, connect the external
memory that holds the FH settings data to
the computer that runs Sysmac Studio.
Then, right-click the FH sensor controller in
the Multiview Explorer and select [Load from
file] from the menu to load the data.

Advertisement

Table of Contents
loading

Table of Contents