Epson DFX-9000 Field Repair Guide
8.
If a .38mm feeler gauge will not fit between the Print Head and the Platen, the gap is too narrow. Loosen Screw
A about 1/8 of a turn. To adjust the gap, insert a flat blade screwdriver into the opening to the left of Screw A.
Twist the screwdriver to change the gap. To increase the gap, move the Upper Angle Bar upwards. Tighten
Screw A when the adjustment is correct.
Screw B
Screw A
Screw C
Printer Component,
Software Item,
Upper Angle Bar
LCD Display,
Printer Button