16. If a .38mm feeler gauge will not fit between the Print Head and the Platen, the gap is too narrow. Loosen Screw
C about 1/8 of a turn. To adjust the gap, insert a flat blade screwdriver into the opening to the right of Screw C.
Twist the screwdriver to change the gap. To increase the gap, move the Upper Angle Bar upwards. Tighten
Screw C when the adjustment is correct.