WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• The CRAVE4836-B/CRAVE4836ST-B, CRAVE6048-B/CRAVE6048ST-B and CRAVE7260-B/CRAVE7260ST-B require a
minimum of 24 inches of vertical venting before attaching any elbow to the appliance.
• The CRAVE8472-B/CRAVE8472ST-B requires a minimum of 36 inches of vertical venting before attaching any elbow to
the appliance.
CRAVE4836-B, CRAVE6048-B, CRAVE7260-B
CRAVE4836ST-B, CRAVE6048ST-B,
CRAVE7260ST-B
V
+ V
Minimum
1
2
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
5 ft.
1.5 m
V
+ H
+ V
= 63 ft. (19.2 m) Maximum
1
1
2
H
= 23 ft. (7.1 m) Maximum
Total
Figure 4.12
Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17
Top Vent - Vertical Termination
Venting with 2 elbows
H Maximum
4 ft.
1.2 m
9 ft.
2.7 m
12 ft.
3.6 m
15 ft.
4.5 m
V
2
Note: Use DVP Series
components only.
H
1
CRAVE8472-B, CRAVE8472ST-B
V
+ V
Minimum
H Maximum
1
2
3 ft.
914 mm
4 ft.
4 ft.
1.2 m
9 ft.
5 ft.
1.5 m
12 ft.
6 ft.
1.8 m
15 ft.
V
+ H
+ V
= 63 ft. (19.2 m) Maximum
1
1
2
H
= 23 ft. (7.1 m) Maximum
Total
V
1
1.2 m
2.7 m
3.6 m
4.5 m
29