[11] Diagnosis

Function
Procedure
You can set a regular interval to diagnose the PSTN interface of the SMG-400.
Setting it to '0' it bypasses the diagnosis. You can set the interval at units of 1sec
by the test type.
1. In the <PSTN Configuration Menu> screen, type '11', and press [Enter].
< < < < < Diagnosis >> > > >
+---+-----------------+---------+--------+--------+
| No |
Diagnosis Items
+---+-----------------+---------+--------+--------+
| 0
| SLI Port Test
| 1
| Trunk Seizure Test
| 2
| Trunk CODEC Test
+---+-----------------+---------+--------+--------+
2. Input the number of the diagnosis interval to be changed, and press [Enter].
Configuration Item Number:
3. Set the diagnosis interval referring to the following table, and press [Enter].
Typed number x 1sec is the actual time.
No
Item
0
SLI Port Test
1
Trunk Seizure Test
2
Trunk CODEC Test
SLI refers to SLC, Trunk refers to LOOP and E&M.
|
Period
|
|
0
|
1 sec
|
0
|
1 sec
|
0
|
1 sec
Description
Sets the diagnosis interval for SLI port test.
It sets the diagnosis interval for trunk seizure
test.
It sets the diagnosis interval for trunk CODEC
test.
5-35
Unit
|
Default
|
|
0
|
|
0
|
|
0
|
[ . :Exit ]