Trunk Signal - Samsung SMG-400 User Manual

Table of Contents

Advertisement

[5] Trunk Signal

Function
Procedure
You can set the signal type for analog and digital trunk.
1. In the <PSTN Configuration Menu> screen, type '5', and press [Enter].
< < < < < Trunk Signal >> > > >
+---+-------------------+---------------+---------+
| No |
Trunk Signal Type
+---+-------------------+---------------+---------+
| 0
|
Insert End Of Digit
+---+-------------------+------+--------+---------+
+---+-------------------+------+--------+---------+
| No |
Trunk Signal Timer
+---+-------------------+------+--------+---------+
| 1
| Seize Time
| 2
| Release Time
| 3
| Noring Time
| 4
| Answer Holding Time
| 5
| CO HookOn Time
+---+-------------------+------+---------+--------+
2. Input the number of the trunk signal type to be changed, and press [Enter].
Configuration Item Number:
|
Value
|
Off
|
Value
|
Unit
|
30
|
10 msec
|
10
| 100 msec
|
4
|
1 sec
|
6
| 100 msec
|
200
|
10 msec
5-23
|
Default
|
|
Off
|
|
Default
|
|
30
|
|
10
|
|
4
|
|
6
|
|
200
|
[ . :Exit ]