Configuring The Cpu Ipv6 Route Table - Avaya ERS 8800 series Configuration Manual

Ipv6 routing ethernet routing switch
Table of Contents

Advertisement

Basic IPv6 configuration using Enterprise Device Manager
Variable
Addr
AddrLen
Type
Type
Origin
Status
Created
LastChanged

Configuring the CPU IPv6 route table

Edit the management port CPU route table to specify network and gateway IP addresses used
to remotely manage the device.
Procedure steps
1. In the Device Physical View tab, select the management port.
2. In the navigation tree, open the following folders: Configuration, Edit.
3. Double-click Mgmt Port.
4. Click the CPU IPv6 Route Table tab.
5. Click Insert.
6. Edit the fields as required.
7. Click Insert.
82
Configuration — IPv6 Routing
The IPv6 address to which this addressing pertains.
Important:
If the IPv6 address exceeds 116 octets, the object identifiers (OIDS)
of instances of columns in this row are more than 128 subidentifiers
and you cannot use SNMPv1, SNMPv2c, or SNMPv3 to access them.
The prefix length value for this address. You cannot change the address
length after creation. You must provide this value to create an entry in
this table. The range is 0-128.
Unicast, the only supported type.
The type of address: unicast or anycast. The default is unicast.
A read-only value indicating the origin of the address. The origin of the
address is other, manual, dhcp, linklayer, or random.
A read-only value indicating the status of the address, describing whether
the address is used for communication. The status is preferred (default),
deprecated, invalid, inaccessible, unknown, tentative, or duplicate.
A read-only value indicating the value of sysUpTime at the time this entry
was created. If this entry was created prior to the last reinitialization of
the local network management subsystem, the object contains a zero
value.
A read-only value indicating the value of sysUpTime at the time this entry
was last updated. If this entry was updated prior to the last reinitialization
of the local network management subsystem, this object contains a zero
value.
Value