EXCELL PRECISION CO., LTD.
Chapter 1 Introduction
1-1 Production Introduction
1. High performance A/D converter
0.3 uv/D high sensitivity
•
Sampling speed 15 times/second
•
non-linear scale 0.01% full scale
•
2. According to different resolution to do linearity calibration
Ordinary resolution models (below 10000)
Do specification calibration first then do weight calibration
High resolution models (10000~30000)
Do linearity calibration first→ specification calibration → weight calibration at last
3. One group of RS232 (option)
4. 5 HOLD functions (contain animal scale HOLD function)
5. LCD display
6. Plug in and rechargeable battery
7. Blackout automatically in order to keep the system stable
(When battery voltage is lower than system voltage, the system will cut the power off
automatically to ensure its stable and accuracy.)
8. LED BACKLIGHT
02018058
zero point adjustable range -2mV~ +5mV
•
use range -4mV ~ +30mV
•
load cell stimulate power source 5V DC ±2% 100mA
•
4
ZSME300000317